• Saudi Med J · Mar 2024

    The impact of sinusitis on dose distribution in a radiotherapy plan by in silico study.

    • Hanan M Alzahrani.
    • From the Department of Radiology Technology, College of Applied Medical Sciences, Taibah University, Al Madinah Al Munawwarah, Kingdom of Saudi Arabia.
    • Saudi Med J. 2024 Mar 1; 45 (3): 235240235-240.

    ObjectivesTo assess the impact of changes in sinus aeration on dose variation in nasopharyngeal cases using a single beam with various field sizes and real patient computed tomography (CT) images.MethodsThe calculations were carried out on a computer equipped with an Intel Xeon (R) Gold 5118 processor operating at 2.30 GHz in 2022 at Taibah University, Al Madinah Al Munawwarah for a retrospective nasopharyngeal case. At the patient level, the impact on dose distribution was examined for different field sizes by comparing the percentage depth dose. The dose discrepancy was evaluated by comparing the dose delivered without considering the anatomical changes observed in the initial fraction to the dose adjusted to account for these changes using a 2D gamma analysis. With a criterion of 1% dose difference and 1 mm distance to agreement, the gamma level for analysis was set at 95%.ResultsThe study findings indicated that the observed effect diminished by approximately 50% for both 5 cm x 5 cm and 10 cm x 10 cm field sizes compared to the 3 cm x 3 cm size, where there was an overlap between the planning target volume and sinusitis.ConclusionThe study concluded that the impact of dose discrepancy was more pronounced in smaller field sizes.Copyright: © Saudi Medical Journal.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…