-
Arch Orthop Trauma Surg · May 2024
Randomized Controlled Trial Multicenter StudyPerformance of medial pivot, posterior stabilized and rotating platform total knee arthroplasty based on anteroposterior stability and patient-reported outcome measures; a multicentre double-blinded randomized controlled trial of 210 knees.
- J D De Groot, R B G Brokelman, P G Lammers, G M J Van Stralen, C M Kooijman, and S T Hokwerda.
- Department of Orthopaedic Surgery, OCON, Geerdinksweg 141, Hengelo, 7555 DL, The Netherlands. jd.de.groot@outlook.com.
- Arch Orthop Trauma Surg. 2024 May 1; 144 (5): 232723352327-2335.
BackgroundDespite advancements in total knee arthroplasty (TKA), 10-20% of patients remain dissatisfied after surgery. Improved anteroposterior (AP) stability provided by medial pivot (MP) implants may theoretically lead to higher patient satisfaction.MethodsAP stability and patient-reported outcome measures (PROMs) at one-year postsurgery were compared between patients who underwent TKA with MP- (n = 121), posterior stabilized (PS; n = 53) and rotating platform (RP; n = 57) implants in a double-blind multicentre randomized controlled trial (Dutch Trial Register: NL6856, 21-02-2018). AP stability was assessed at 30°, 60° and 90° of knee flexion using a KT-2000 arthrometer. PROMs were measured preoperative and one-year postsurgery.ResultsMP-TKA provided significant better AP stability at early flexion (30°) compared to PS- and RP-TKA (median [IQR]; 1.79 [1.14-2.77] mm vs. 3.31 [2.51-4.08] mm vs. 2.82 [1.80-4.03] mm, p < 0.001). Additionally, MP-TKA provided significant better AP stability at mid-flexion (60°) compared to PS-TKA (1.75 [1.23-2.36] mm vs. 2.14 [1.49-2.83] mm, p = 0.014). PROM improvements were comparable between implant designs. AP laxity of ≥ 4 mm at early flexion was independently of implant design associated with significantly worse Kujala scores. The incidence of ≥ 4 mm AP laxity at any knee angle was however not significantly different between implant designs.ConclusionMP-, PS- and RP-TKA all provide excellent and comparable results. Although MP-TKA provided better AP stability at early flexion compared to PS- and RP-TKA, this was found to be unrelated to improved PROMs in favour of MP-TKA. More studies focusing on early and mid-flexion performance based differences between MP and other TKA designs are required to confirm our findings. Other non-implant related factors may play a more important role in the performance of TKA and are potentially worthwhile examining.© 2024. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.