Randomized Controlled Trial
Impact of Real-Time Assessment of Pulse Oximetry on the 6-Min Walk Distance in Patients With Chronic Respiratory Disease.
- Litiele E Wagner, Gustavo H Rosa, Franciele Plachi, Amanda Becker da Silva, Ariane da S Imperador, Anna Carolina de Azevedo, Marcelo B Gazzana, J Alberto Neder, and Danilo C Berton.
- Programa de Pós-Graduação em Ciências Pneumológicas, Universidade Federal do Rio Grande do Sul, Hospital de Clínicas de Porto Alegre, Rio Grande do Sul, Brazil.
- Respir Care. 2024 Sep 26; 69 (10): 129413041294-1304.
BackgroundContinuous monitoring of pulse oximetry (SpO2 ) is recommended during the 6-min walk test (6MWT) to ensure that the lowest SpO2 is recorded. In this case, severe exercise-induced desaturation (EID; SpO2 < 80%) triggers walking interruption by the examiner. Our main objective was to assess the impact of this approach on 6MWT distance in patients with chronic respiratory diseases and, second, to evaluate the safety of the test without interruption due to severe EID.Methods6MWTs with continuous monitoring of SpO2 were prospectively performed in subjects with chronic respiratory disease. The participants were randomly allocated to walk with or without SpO2 real-time assessment. SpO2 visualization during the test execution was available only in the first group, and walking interruption was requested by the examiner if SpO2 < 80%.ResultsOne hundred forty-five participants were included in each group (68.6% females, 62 [52-69] y old) without differences in demographic and resting lung function parameters between them. The main respiratory conditions were COPD (n = 101), asthma (n = 73), pulmonary hypertension (n = 47), and interstitial lung disease (n = 39). The walked distance was similar comparing groups (349.5 ± 117.5 m vs 351.2 ± 105.4 m). Twenty-five subjects presented with severe EID in the group with real-time SpO2 assessment, and 20 subjects had severe EID in the group without real-time assessment respectively (overall prevalence of 15.5%). The 23 participants who had their test interrupted by the examiner due to severe EID in the first group (2 subjects stopped by themselves due to excessive symptoms) walked a shorter distance compared to the 11 subjects with severe EID without test interruption in the second group (9 subjects stopped by themselves due to excessive symptoms): 240.6 ± 100.2 m versus 345.9 ± 73.4 m. No exercise-related serious adverse events were observed.ConclusionsInterruption driven by severe EID reduced the walked distance during the 6MWT. No serious adverse event, in turn, was observed in subjects with severe desaturation without real-time SpO2 assessment.Copyright © 2024 by Daedalus Enterprises.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.