- David W Healy, Paul Picton, Michelle Morris, and Christopher Turner.
- Department of Anesthesiology, The University of Michigan, 1500 E, Medical Center Dr,, 1H247, SPC 5048, Ann Arbor, MI, 48109-5048, USA. dhealy@med.umich.edu.
- BMC Anesthesiol. 2012 Jan 1;12:11.
UnlabelledBackgroundVideolaryngoscopy presents a new approach for the management of the difficult and rescue airway. There is little available evidence to compare the performance features of these devices in true difficult laryngoscopy.MethodsA prospective randomized crossover study was performed comparing the performance features of the Macintosh Laryngoscope, Glidescope, Storz CMAC and Storz DCI videolaryngoscope. Thirty anesthesia providers attempted intubation with each of the 4 laryngoscopes in a high fidelity difficult laryngoscopy manikin. The time to successful intubation (TTSI) was recorded for each device, along with failure rate, and the best view of the glottis obtained.ResultsUse of the Glidescope, CMAC and Storz videolaryngoscopes improved the view of the glottis compared with use of the Macintosh blade (GEE, p = 0.000, p = 0.002, p = 0.000 respectively). Use of the CMAC resulted in an improved view compared with use of the Storz VL (Fishers, p = 0.05). Use of the Glidescope or Storz videolaryngoscope blade resulted in a longer TTSI compared with either the Macintosh (GLM, p = 0.000, p = 0.029 respectively) or CMAC blades (GLM, p = 0.000, p = 0.033 respectively).ConclusionsUnsurprisingly, when used in a simulated difficult laryngoscopy, all the videolaryngoscopes resulted in a better view of the glottis than the Macintosh blade. However, interestingly the CMAC was found to provide a better laryngoscopic view that the Storz DCI Videolaryngoscope. Additionally, use of either the Glidescope or Storz DCI Videolaryngoscope resulted in a prolonged time to successful intubation compared with use of the CMAC or Macintosh blade. The use of the CMAC during manikin simulated difficult laryngoscopy combined the efficacy of attainment of laryngoscopic view with the expediency of successful intubation. Use of the Macintosh blade combined expedience with success, despite a limited laryngoscopic view. The limitations of a manikin model of difficult laryngoscopy limits the conclusions for extrapolation into clinical practice.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.