-
Observational Study
Utility of Second-look Ultrasonography in Distinguishing BI-RADS 4 Calcifications Detected on Mammography: An observational study.
- Sheng Cheng, Lin Zhu, Ning Lin, Muzhen He, Yingbin Yu, Mengbo Lin, and Hui Zhang.
- Department of Ultrasonography, Shengli Clinical Medical College of Fujian Medical University, Fujian Provincial Hospital, Fuzhou University Affiliated Provincial Hospital, Fuzhou, Fujian Province, China.
- Medicine (Baltimore). 2024 Jul 12; 103 (28): e38841e38841.
AbstractThis study aimed to assess the utility of second-look ultrasonography (US) in differentiating breast imaging reporting and data system (BI-RADS) 4 calcifications initially detected on mammography (MG). BI-RADS 4 calcifications have a wide range of positive predictive values. We hypothesized that second-look US would help distinguish BI-RADS 4 calcifications without clinical manifestations and other abnormalities on MG. This study included 1622 pure BI-RADS 4 calcifications in 1510 women (112 patients with bilateral calcifications). The cases were randomly divided into training (85%) and testing (15%) datasets. Two nomograms were developed to differentiate BI-RADS 4 calcifications in the training dataset: the MG-US nomogram, based on multifactorial logistic regression and incorporated clinical information, MG, and second-look US characteristics, and the MG nomogram, based on clinical information and mammographic characteristics. Calibration of the MG-US nomogram was performed using calibration curves. The discriminative ability and clinical utility of both nomograms were compared using the area under the receiver operating characteristic curve (AUC) and the decision analysis curve (DCA) in the test dataset. The clinical information and imaging characteristics were comparable between the training and test datasets. The bias-corrected calibration curves of the MG-US nomogram closely approximate the ideal line for both datasets. In the test dataset, the MG-US nomogram exhibited a higher AUC than the MG nomogram (0.899 vs 0.852, P = .01). DCA demonstrated the superiority of the MG-US nomogram over the MG nomogram. Second-look US features, including ultrasonic calcifications, lesions, and moderate or marked color flow, were valuable for distinguishing BI-RADS 4 calcifications without clinical manifestations and other abnormalities on MG.Copyright © 2024 the Author(s). Published by Wolters Kluwer Health, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.