Randomized Controlled Trial Comparative Study
A Cluster-Randomized Control Study Comparing a New Cue "Two Compressions per Second" with "100-120 Compressions per Minute" in Training of Bystander Cardiopulmonary Resuscitation.
- Ming-Ju Hsieh, Hao-Yang Lin, Ying-Chih Ko, Chih-Wei Yang, Wen-Chu Chiang, and Matthew Huei-Ming Ma.
- Department of Emergency Medicine. Electronic address: erdrmjhsieh@gmail.com.
- J Emerg Med. 2024 Nov 1; 67 (5): e425e431e425-e431.
BackgroundChest compression at a rate of 100-120 compressions per minute (cpm) during cardiopulmonary resuscitation (CPR) is associated with the highest survival rates. Performing compressions at a faster rate may exhaust the rescuers.ObjectivesTo compare a new cue of 'two compressions per second' to the traditional cue of '100-120 compressions per minute' on compression rate in CPR training.MethodsIn this cluster-randomized study, students from two senior high schools were assigned into two groups. For the experimental group, the cue for the compression rate was 'two compressions per second'. For the control group, the cue was '100-120 cpm'. Except the different cues, all participants underwent the same standardized CPR training program. Verbal compression rate-related feedback was not obtained during practice. Quality indicators of chest compressions were recorded by a sensorized manikin. The primary outcome measure was mean compression rate at course conclusion. The secondary outcome measures were individual compression quality indicators at course conclusion and 3 months after training.ResultsWe included 164 participants (85 participants, experimental group; 79 participants, control group). Both groups had similar characteristics. The experimental group had a significantly lower mean compression rate at course conclusion (144.3 ± 16.17 vs. 152.7 ± 18.38 cpm, p = 0.003) and at 3 months after training (p = 0.09). The two groups had similar mean percentage of adequate compression rate (≥ 100 cpm), mean compression depth, and mean percentage of complete recoil at course conclusion and 3 months after training.ConclusionThe new cue of 'two compressions per second' resulted in participants having a lower compression rate, although it still exceeded 120 cpm.Copyright © 2024 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.