    Comparative Analysis of Somatosensory-evoked Potentials and Transcranial Doppler Ultrasound for Cerebral Ischemia Detection in Carotid Endarterectomy: Insights from Network Meta-Analysis and Clinical Data.

    • Dejing Cheng, Siyuan Yang, and Chengyuan Ji.
    • The Forth Affiliated Hospital of Soochow University, Su Zhou, China.
    • World Neurosurg. 2024 Sep 10.

    ObjectiveThis study aims to compare the diagnostic efficacy of somatosensory-evoked potentials (SEPs) and transcranial Doppler sonography (TCD) for monitoring cerebral tissue ischemia during carotid endarterectomy (CEA) using network meta-analysis and retrospective analysis of clinical data.MethodsFor the meta-analysis, we conducted a comprehensive search of 4 electronic databases (PubMed, EMBASE, Cochrane, and Web of Science) from inception to September 2023, resulting in the inclusion of 52 relevant articles. Additionally, a retrospective study was conducted at our hospital, involving patients who underwent CEA surgery from July 2019 to July 2021.ResultsThe network meta-analysis incorporated 52 articles, with ranking results indicating that SEP demonstrated superior performance in specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy with surface under the cumulative ranking curve values of 99.9%, 93.8%, 96.6%, and 99.9%, respectively. Furthermore, TCD exhibited the highest sensitivity with a surface under the cumulative ranking value of 92.0%. A total of 190 patients meeting inclusion criteria were included in the retrospective study. The area under the curve for SEP's receiver operating characteristic curve was 0.787, compared to TCD's area under the curve of 0.606. SEP demonstrated a sensitivity of 66.67%, with a specificity of 90.76%, PPV of 19.05%, NPV of 98.82%, and accuracy of 90%. For TCD, the diagnostic performance measures included a sensitivity of 50.00%, specificity of 71.19%, PPV of 5.35%, NPV of 97.76%, and accuracy of 70.53%. The Fisher's exact test for sensitivity yielded a result of P = 1.000. The χˆ2 test for specificity resulted in χˆ2 = 22.863, with P < 0.001. Continuous correction χˆ2 tests for PPV and NPV showed χˆ2 = 2.005 (P = 0.157) and χˆ2 = 0.069 (P = 0.793), respectively. Additionally, the χˆ2 test for accuracy showed χˆ2 = 22.742, with P < 0.001.ConclusionsDuring CEA, SEP appears to provide a slightly more reliable indication of the ischemic condition in cerebral tissues compared to TCD.Copyright © 2024 The Authors. Published by Elsevier Inc. All rights reserved.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…