-
- Karen R Boretsky, Viviane G Nasr, Douglas Atkinson, and Martin Baruch.
- Boston Children's Hospital Department of Anesthesiology Critical Care and Pain Medicine, Boston Children's Hospital, 300 Longwood Avenue, Boston, MA 02115, United States of America. Electronic address: Karen.boretsky@childrens.harvard.edu.
- J Clin Anesth. 2025 Jan 23; 102: 111763111763.
BackgroundAccurate blood pressure monitoring is essential in many clinical scenarios for adults and children and, when continuous measurement is critical, necessitates the insertion of an arterial line. A novel continuous non-invasive arterial pressure monitoring device using a pulse contour algorithm (Pulse Decomposition Analysis), Vitalstream™, is approved by the United States Food and Drug Administration for use in adults. In this study the performance and accuracy of the device compared to intraarterial blood pressure monitoring were assessed in children ages 2-17 undergoing major surgeries. We report the results using comparison to aspects of the recently published ISO 81060-3:2022 standard for continuous automated blood pressure measurement.Methods31 children ages 2-17 years scheduled for major surgery requiring invasive arterial blood pressure monitoring were consented to participate. Systolic, diastolic, and mean arterial blood pressure readings were obtained from both systems during at least thirty minutes of simultaneous monitoring during hemodynamically stable periods of the surgical procedure and statistically compared.ResultsThe correlations of systolic and, diastolic, and mean arterial pressures were, respectively, 0.77, 0.68 and 0.7. The Bland-Altman comparisons yielded bias of -3.79 (9.74) mmHg, 1.72 (8.45) mmHg and 2.41 (8.75) mmHg respectively, for systolic, diastolic, and mean arterial pressures, (p < 0.001 for all comparisons). Concordances for systole, diastole and MAP were, respectively, 0.82, 0.85 and 0.83.ConclusionsMost values fell within +/-20mmhg of the corresponding arterial line values. While this meets the basic requirement for such devices published by professional societies, clinicians will need to be aware of the potential variances and make clinical decisions accordingly. The Vitalstream™ may offer low risk, accurate continuous pressure monitoring in children ages 2-17.Clinical Trialsgov: NCT04817137 The trial was registered at clinicaltrials.gov (NCT048I7173).Copyright © 2024. Published by Elsevier Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.