• Z Gastroenterol · Mar 2002

    Comparative Study

    [HYGEA (Hygiene in gastroenterology--endoscope reprocessing): Study on quality of reprocessing flexible endoscopes in hospitals and in the practice setting].

    • L Bader, G Blumenstock, B Birkner, O Leiss, J Heesemann, J F Riemann, and H-K Selbmann.
    • Max von Pettenkofer-Institut für Hygiene und Medizinische Mikrobiologie (Lehrstuhl Bakteriologie), Ludwig-Maximilians-Universität München. bader_lutz@m3401.mpk.med.uni-muenchen.de
    • Z Gastroenterol. 2002 Mar 1;40(3):157-70.

    AbstractThe quality of reprocessing gastroscopes, colonoscopes and duodenoscopes in daily routine of 25 endoscopy departments in hospitals and 30 doctors with their own practices was evaluated by microbiological testing in the HYGEA interventional study. In 2 test periods, endoscopes ready for use in patients were found contaminated at high rates (period 1: 49 % of 152 endoscopes; period 2: 39 % of 154 endoscopes). Culture of bacterial fecal flora (E. coli, coliform enterobacteriaceae, enterococci) was interpreted indicating failure of cleaning procedure and disinfection of endoscopes. Detection of Pseudomonas spp. (especially P. aeruginosa) and other non-fermenting rods - indicating microbially insufficient final rinsing and incomplete drying of the endoscope or a contaminated flushing equipment for the air/water-channel - pointed out endoscope recontamination during reprocessing or afterwards. Cause for complaint was found in more than 50 % of endoscopy facilities tested (period 2: 5 in hospitals, 25 practices). Reprocessing endoscopes in fully automatic chemo-thermally decontaminating washer-disinfectors with disinfection of final rinsing water led to much better results than manual or semi-automatic procedures (failure rate of endoscopy facilities in period 2 : 3 of 28 with fully automatic, 8 of 12 with manual, 9 of 15 with semi-automatic reprocessing). The study results give evidence for the following recommendations: 1. Manual brushing of all accessible endoscope channels has to be performed even before further automatic reprocessing; 2. For final endoscope rinsing, water or aqua dest. should only be used disinfected or sterile-filtered; 3. Endoscopes have to be dried thoroughly using compressed air prior to storage; 4. Bottle and tube for air/water-channel flushing have to be reprocessed daily by disinfection or sterilization, and in use, the bottle have to be filled exclusively with sterile water. The HYGEA study shows that microbiological testing of endoscopes is useful for detection of insufficient reprocessing and should be performed for quality assurance in doctors' practices, too. The study put recommendations for reprocessing procedures in more concrete terms.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.