• Transplant. Proc. · Mar 2012

    Comparative Study

    Cardiac output derived from arterial pressure waveform analysis: validation of the third-generation software in patients undergoing orthotopic liver transplantation.

    • Y-F Tsai, B-C Su, C-C Lin, F-C Liu, W-C Lee, and H-P Yu.
    • Department of Anesthesiology, Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Tao-Yuan, Taiwan.
    • Transplant. Proc. 2012 Mar 1;44(2):433-7.

    BackgroundThe upgraded third-generation software (version 3.02) for the FloTrac/Vigileo system has been developed to particularly improve the accuracy of cardiac output (CO) measurements in hyperdynamic conditions. The aim of our study was to compare the CO values obtained using the FloTrac/Vigileo system during orthotopic liver transplantation (OLT) with those obtained in the same circumstances using a Swan-Ganz catheter (bolus thermodilution method).MethodsTwenty consecutive recipients scheduled for OLT were studied. Simultaneous CO values measured by both devices were obtained at 10 predefined time points throughout the surgery. A percentage error of not more than 30% was established as the criterion for device interchangeability.ResultsA total of 200 paired measurements were obtained. The CO values derived from the FloTrac/Viligeo ranged from 2.8 to 10.9 L/min, with a mean of 5.91±1.81 L/min. The values from bolus thermodilution ranged from 2.2 to 13.2 L/min, with a mean of 6.12±2.07 L/min. The bias was 0.22, and the limits of agreement were -3.13 to 3.56 L/min. The percentage error between the FloTrac/Viligeo and bolus thermodilution measurements was 54.93%. The percentage errors of paired measurements in three surgical phases by subgroup analysis were 43.50% (dissecting phase), 62.9% (anhepatic phase), and 56.05% (reperfusion phase), respectively.ConclusionCO measurements obtained using the less invasive arterial waveform FloTrac/Vigileo system upgraded with the third-generation software had poor intraoperative agreement with pulmonary artery thermodilution CO measurements in patients undergoing OLT.Copyright © 2012 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.