• Ann Emerg Med · Mar 1991

    Randomized Controlled Trial Clinical Trial

    Preliminary evaluation of a prototype tube-valve-mask ventilator for emergency artificial ventilation.

    • P R Giffen and C E Hope.
    • Department of Anaesthesia, Faculty of Medicine, Dalhousie University, Halifax, Nova Scotia, Canada.
    • Ann Emerg Med. 1991 Mar 1;20(3):262-6.

    Study ObjectiveThe objective was to design a prototype tube-valve-mask ventilator that would permit relatively inexperienced operators to provide adequate emergency artificial ventilation, namely, adequate ventilatory volumes and a high oxygen and low carbon dioxide delivery.DesignThe tube-valve-mask ventilator is powered by the exhaled air of the operator and uses a tube to act as an oxygen reservoir (1,300 mL) that is filled between breaths. Mouth-to-mouth breathing was the standard against which the tube-valve-mask ventilator and the other accepted methods of mouth-to-mask and bag-valve-mask were assessed.SettingComparison studies were conducted during simulated two-person CPR using a training mannikin equipped to measure ventilation volume and delivered oxygen and carbon dioxide concentrations.Type Of ParticipantsSeventeen volunteer first-year nursing students were used as operators.InterventionsThe order in which the pairs of operators performed each of the techniques was randomized.Measurements And Main ResultsThe ventilation volume and the percentage of oxygen and carbon dioxide delivered by each technique were as follows (mean +/- SD): Mouth-to mouth (760 +/- 290 mL, 17 +/- 1% O2, 3.4 +/- 0.4% CO2), mouth-to-mask (910 +/- 350 mL, 41 +/- 8% O2, 2.5 +/- 0.4% CO2), bag-valve-(soft) mask (550 +/- 230 mL, 94 +/- 3% O2, 0.03 +/- 0.02% CO2), bag-valve-(rigid) mask (560 +/- 300 mL, 96 +/- 3% O2, 0.03 +/- 0.02% CO2), and tube-valve-mask (860 +/- 290 mL, 91 +/- 7% O2, 0.2 +/- 0.2% CO2).ConclusionIn the hands of relatively inexperienced operators, mouth-to-mouth, mouth-to-mask, and tube-valve-mask techniques provide adequate ventilation volumes to a mannikin. This was not the case with the bag-valve-mask systems (800 mL; P = .05 by t test). Of the systems that provide adequate ventilation volume, the tube-valve-mask appears, superior in that higher oxygen and lower carbon dioxide concentrations can also be obtained (P = .05 by paired t test).

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.