• IEEE Trans Med Imaging · Oct 2005

    Improving geometric accuracy in the presence of susceptibility difference artifacts produced by metallic implants in magnetic resonance imaging.

    • Yves Pauchard, Michael R Smith, and Martin P Mintchev.
    • Department of Electrical and Computer Engineering, University of Calgary, Calgary, Canada.
    • IEEE Trans Med Imaging. 2005 Oct 1;24(10):1387-99.

    AbstractGeometric and intensity distortions due to the presence of metallic implants in magnetic resonance imaging impede the full exploitation of this advanced imaging modality. The aim of this study is to provide a method for (a) quantifying and (b) reducing the implant distortions in patient images. Initially, a set of reference images (without distortion) was obtained by imaging a custom-designed three-dimensional grid phantom. Corresponding test images (containing the distortion) were acquired with the same imaging parameters, after positioning a specific metallic implant in the grid phantom. After determining: 1) the nonrecoverable; 2) the distorted, but recoverable; and 3) the unaffected areas, a point-based thin-plate spline image registration algorithm was employed to align the reference and test images. The calculated transformation functions utilized to align the image pairs described the implant distortions and could therefore be used to correct any other images containing the same distortions. The results demonstrate successful correction of grid phantom images with a metallic implant. Furthermore, the calculated correction was applied to porcine thigh images bearing the same metallic implant, simulating a patient environment. Qualitative and quantitative assessments of the proposed correction method are included.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.