• J Clin Monit Comput · Dec 2016

    Comparative Study Observational Study

    Comparison of the accuracy of hemoglobin point of care testing using HemoCue and GEM Premier 3000 with automated hematology analyzer in emergency room.

    • Jan Zatloukal, Jiri Pouska, Jakub Kletecka, Richard Pradl, and Jan Benes.
    • Department of Anesthesiology and Intensive Care, The Faculty of Medicine, The University Hospital, Plzen - Charles University Prague, alej Svobody 80, 304 60, Plzeň, Czech Republic. zatloukalj@fnplzen.cz.
    • J Clin Monit Comput. 2016 Dec 1; 30 (6): 949-956.

    AbstractThe laboratory analysis provides accurate, but time consuming hemoglobin level estimation especially in the emergency setting. The reliability of time-sparing point of care devices (POCT) remains uncertain. We tested two POCT devices accuracy (HemoCue(®)201(+) and Gem(®)Premier™3000) in routine emergency department workflow. Blood samples taken from patients admitted to the emergency department were analyzed for hemoglobin concentration using a laboratory reference Beckman Coulter LH 750 (HBLAB), the HemoCue (HBHC) and the Gem Premier 3000 (HBGEM). Pairwise comparison for each device and HbLAB was performed using correlation and the Bland-Altman methods. The reliability of transfusion decision was assessed using three-zone error grid. A total of 292 measurements were performed in 99 patients. Mean hemoglobin level were 115 ± 33, 110 ± 28 and 111 ± 30 g/l for HbHC, HbGEM and HbLAB respectively. A significant correlation was observed for both devices: HbHC versus HbLAB (r(2) = 0.93, p < 0.001) and HBGEM versus HBLAB (r(2) = 0.86, p < 0.001). The Bland-Altman method revealed bias of -3.7 g/l (limits of agreement -20.9 to 13.5) for HBHC and HBLAB and 2.5 g/l (-18.6 to 23.5) for HBGEM and HBLAB, which significantly differed between POCT devices (p < 0.001). Using the error grid methodology: 94 or 91 % of values (HbHC and HbGEM) fell in the zone of acceptable difference (A), whereas 0 and 1 % (HbHC and HbGEM) were unacceptable (zone C). The absolute accuracy of tested POCT devices was low though reaching a high level of correlation with laboratory measurement. The results of the Morey´s error grid were unfavorable for both POCT devices.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…