• J. Appl. Physiol. · Mar 1997

    Human respiratory input impedance between 32 and 800 Hz, measured by interrupter technique and forced oscillations.

    • U Frey, B Suki, R Kraemer, and A C Jackson.
    • Department of Biomedical Engineering, Boston University Massachusetts 02215, USA.
    • J. Appl. Physiol. 1997 Mar 1;82(3):1018-23.

    AbstractRespiratory input impedance (Zin) over a wide range of frequencies (f) has been shown to be useful in determining airway resistance (Raw) and tissue resistance in dogs or airway wall properties in human adults. Zin measurements are noninvasive and, therefore, potentially useful in investigation of airway mechanics in infants. However, accurate measurements of Zin at these f values with the use of forced oscillatory techniques (FOT) in infants are difficult because of their relatively high Raw and large compliance of the face mask. If pseudorandom noise pressure oscillations generated by a loudspeaker are applied at the airway opening (FOT), the power of the resulting flow decreases inversely with f because of capacitive shunting into the volume of the gas in the speaker chamber and in the face mask. We studied whether high-frequency respiratory Zin can be measured by using rapid flow interruption [high-speed interrupter technique (HIT)], in which we expect the flow amplitude in the respiratory system to be higher than in the FOT. We compared Zin measured by HIT with Zin measured by FOT in a dried dog lung and in five healthy adult subjects. The impedance was calculated from two pressure signals measured between the mouth and the HIT valve. The impedance could be assessed from 32 to 800 Hz. Its real part at low f as well as the f and amplitude of the first and second acoustic resonance, measured by FOT and by HIT, were not significantly different. The power spectrum of oscillatory flow when the HIT was used showed amplitudes that were at least 100 times greater than those when FOT was used, increasing at f > 400 Hz. In conclusion, the HIT enables the measurement of high-frequency Zin data ranging from 32 to 800 Hz with particularly high flow amplitudes and, therefore, possibly better signal-to-noise ratio. This is particularly important in systems with high Raw, e.g., in infants, when measurements have to be performed through a face mask.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.