Journal of applied physiology
-
Respiratory input impedance (Zin) over a wide range of frequencies (f) has been shown to be useful in determining airway resistance (Raw) and tissue resistance in dogs or airway wall properties in human adults. Zin measurements are noninvasive and, therefore, potentially useful in investigation of airway mechanics in infants. However, accurate measurements of Zin at these f values with the use of forced oscillatory techniques (FOT) in infants are difficult because of their relatively high Raw and large compliance of the face mask. ⋯ The power spectrum of oscillatory flow when the HIT was used showed amplitudes that were at least 100 times greater than those when FOT was used, increasing at f > 400 Hz. In conclusion, the HIT enables the measurement of high-frequency Zin data ranging from 32 to 800 Hz with particularly high flow amplitudes and, therefore, possibly better signal-to-noise ratio. This is particularly important in systems with high Raw, e.g., in infants, when measurements have to be performed through a face mask.