• Resp Care · Dec 2008

    Bench study on active exhalation valve performance.

    • Guang-Yu Jiao and John W Newhart.
    • Respiratory Department, Shengjing Hospital, China Medical University, Shenyang, Peoples Republic of China. guangyujiao@yahoo.com
    • Resp Care. 2008 Dec 1;53(12):1697-702.

    BackgroundVentilator exhalation-valve performance during the expiratory phase has been studied in depth. An active exhalation valve uses servo-control technology that allows gas to be released from the exhalation valve during the inspiratory phase if the patient makes an expiratory effort. We conducted a bench study of active exhalation valve response to expiratory effort during the inspiratory phase.MethodsWe studied 4 ventilators that have active exhalation valves (Maquet Servo-i, Newport e500, Puritan Bennett 840, and Evita XL) and one that does not (Puritan Bennett 7200ae). With an active test lung we simulated various magnitudes of expiratory effort during the middle of the inspiratory phase. We measured the exhalation resistance and pressure over-shoot during the expiratory effort, and we measured the pressure under-shoot after the expiratory effort. The exhalation resistance of the 7200ae could not be determined because this ventilator did not allow any gas-release through the exhalation valve during the expiratory effort.ResultsThe exhalation resistance of the Evita XL (6.6 +/- 1.8 cm H(2)O/L/s) was higher than that of the Servo-i (3.0 +/- 1.3 cm H(2)O/L/s), e500 (2.6 +/- 0.8 cm H(2)O/L/s), and 840 (3.5 +/- 0.8 cm H(2)O/L/s) (all P < .001). The magnitude of pressure over-shoot during the expiratory efforts was not significantly different among the 4 ventilators with active exhalation valves. Pressure over-shoot was significantly higher with the 7200ae than with any of other ventilators (all P < .001).ConclusionsThere was a significant difference in exhalation resistance between the Evita XL and the other 3 ventilators with active exhalation valves. All 4 ventilators with active exhalation valves had lower exhalation resistance than the 7200ae.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…