Experience at a single institution with endovascular treatment of mechanical complications caused by implanted central venous access devices in pediatric and adult patients.
- Bertrand Bessoud, Thierry de Baere, Viseth Kuoch, Eric Desruennes, Marie-France Cosset, Nathalie Lassau, and Alain Roche.
- Department of Interventional Radiology, Institut Gustave Roussy, 39 rue Camille Desmoulins, 94805 Villejuif, France.
- AJR Am J Roentgenol. 2003 Feb 1;180(2):527-32.
ObjectiveOur objective was to describe the technical aspects and evaluate the feasibility, safety, and efficacy of endovascular management of mechanical complications related to implanted central venous devices.Materials And MethodsOne hundred fifty-six patients with cancer, who ranged in age from 3 months to 75 years (mean +/- SD, 47 +/- 18 years), were referred 290 +/- 200 days (mean +/- SD; range, 0-1202 days) after central venous device placement for retrieval of a fractured and embolized central venous device catheter (n = 100), retrieval of a guidewire embolized during placement of a central venous device (n = 2), repositioning of the migrated tip of a central venous device catheter (n = 38), and fibrin-sheath stripping (n = 16). All procedures were performed with the patient under local anesthesia on an outpatient basis, except for the eight pediatric patients.ResultsNinety-five of the 100 embolized catheters and both of the guidewires were successfully retrieved. Retrieval was preceded by repositioning the embolized catheter with a pigtail catheter in 48 of these cases. Most of the procedures were performed with standard vascular tools (loop snares and pigtail catheters); the use of more sophisticated devices (grasping forceps, baskets, or balloons) rarely overcame the failure of a loop snare. Repositioning a migrated catheter tip was achieved with a pigtail catheter in 32 of 38 attempts. Of the repositioned catheters, only 24 could be used. Most of the 11 repositioning and retrieval failures were encountered because the catheter lacked a free end. Fibrin-sheath stripping was always technically successful: all these catheters were patent at 3-month follow-up. No procedure-related complications occurred.ConclusionThe endovascular approach is highly feasible, safe, and effective for the management of mechanical complications of central venous devices. It is probably advisable to reserve endovascular repositioning for port catheters that are cumbersome to exchange and to replace simple catheters.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.