J Anaesthesiol Clin Pharmacol · Jul 2013
Assessment of cervical spine movement during laryngoscopy with Macintosh and Truview laryngoscopes.
- Neerja Bhardwaj, Kajal Jain, Madhusudan Rao, and Arup Kumar Mandal.
- Department of Anesthesia and Intensive Care, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
- J Anaesthesiol Clin Pharmacol. 2013 Jul 1;29(3):308-12.
BackgroundTruview laryngoscope provides an indirect view of the glottis and will cause less cervical spine movement since a ventral lifting force will not be required to visualize the glottis compared to Macintosh laryngoscope.Materials And MethodsA randomized crossover study to assess the degree of movement of cervical spine during endotracheal intubation with Truview laryngoscope was conducted in 25 adult ASA-I patients. After a standard anesthetic technique laryngoscopy was performed twice in each patient using in turn both the Macintosh and Truview laryngoscopes. A baseline radiograph with the head and neck in a neutral position was followed by a second radiograph taken during each laryngoscopy. An experienced radiologist analyzed and measured the cervical movement.ResultsSignificant cervical spine movement occurred at all segments when compared to the baseline with both the Macintosh and Truview laryngoscopes (P < 0.001). However, the movement was significantly less with Truview compared to the Macintosh laryngoscope at C0-C1 (21%; P = 0.005) and C1-C2 levels (32%; P = 0.009). The atlantooccipital distance (AOD) traversed while using Truview laryngoscope was significantly less than with Macintosh blade (26%; P = 0.001). Truview blade produced a better laryngoscopic view (P = 0.005) than Macintosh blade, but had a longer time to laryngoscopy (P = 0.04).ConclusionTruview laryngoscope produced a better laryngoscopic view of glottis as compared with Macintosh laryngoscopy. It also produced significantly less cervical spine movement at C0-C1 and C1-C2 levels than with Macintosh laryngoscope in patients without cervical spine injury and without manual in-line stabilization (MILS). Further studies are warranted with Truview laryngoscope using MILS.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.