• Resp Care · Nov 2003

    Clinical Trial

    The effect of arterial blood gas values on extubation decisions.

    • Adil Salam, Mihai Smina, Pritee Gada, Lisa Tilluckdharry, Anupama Upadya, Yaw Amoateng-Adjepong, and Constantine A Manthous.
    • Department of Internal Medicine, Bridgeport Hospital, Yale University, CT 06610, USA.
    • Resp Care. 2003 Nov 1;48(11):1033-7.

    BackgroundNo studies have examined the clinical utility of arterial blood gas (ABG) values during spontaneous breathing trials (SBTs) for making extubation decisions. Nonetheless many intensive care units measure ABGs during an SBT to determine, in conjunction with other data, whether the SBT was successful.ObjectiveDetermine how often ABG values change extubation decisions.MethodsEach patient was assessed at the bedside by one of 3 critical care attending physicians. Each assessment was made at the end of the SBT in which ABGs were obtained with the expectation of extubation. When a nurse, respiratory therapist, or resident was available, he or she also simultaneously and independently evaluated the patient and then reassessed with the ABG values. Physiologic data were recorded before and during the SBT, as the attending physician performed the bedside assessment.ResultsEighty-three patients were studied during 100 SBTs. Heart rate, respiratory rate, and mean blood pressure increased. Blood oxygen saturation (measured via pulse oximetry [F(IO)(2)]) and the P(aO)(2)/F(IO)(2) ratio decreased significantly during SBTs. Concordant clinical and ABG assessment (to attempt a trial of extubation) led to extubation in 86 patients, 76 of whom remained extubated after 72 hours. Following 14 of the SBTs, the patients were not extubated. Seven of these were judged by the attending physicians to fail both clinically and following review of ABG values. Seven were judged successful clinically, but the patients were not extubated because the attending physician thought the ABG values were unfavorable. Bedside nurses, who assessed 72 SBTs, had 1 case in which the ABG values changed their extubation opinion. Resident-trainees assessed 76 cases and had 5 changes of opinion based on ABG values. Respiratory therapists assessed 77 patients and had 4 such cases. The average changes in heart rate and blood pressure of patients not extubated were double those of extubated patients, but there were no significant differences in respiratory rate or P(aO)(2)/F(IO)(2) ratio between those groups. Ten patients (11.6%) were extubated based on the attending physician's decision but required re-intubation within 72 hours.ConclusionThese data suggest that ABG values did not change extubation decisions in 93% of cases. However, in 7 cases the ABG values changed the extubation decision. If even a few of those cases would have failed extubation without knowledge of the ABG values, the increased patient risk and cost associated with failed extubation would more than offset the relatively small cost of collecting ABG values from all patients who undergo SBT.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…