-
- Brian L Tiep, James Barnett, George Schiffman, Oscar Sanchez, and Rick Carter.
- Pulmonary Care Continuum, 5467 2nd Street, Irwindale, CA 91706, USA.
- Resp Care. 2002 Aug 1;47(8):887-92.
BackgroundOxygen-conserving devices have been the foundation of highly portable oxygen systems that enable hypoxemic chronic lung disease patients to live active lives. Pulsing demand oxygen delivery systems (DODS) can adequately oxygenate most patients at rest and usually during exercise. However, some patients desaturate during exercise at DODS settings equivalent to continuous-flow oxygen.ObjectiveDetermine if design enhancements of the Oxymatic 401 DODS (including increased sensitivity, earlier inspiratory delivery, larger pulse volume, modified pulse contour, and higher settings) better maintain blood oxygen saturation (measured via pulse oximetry [S(pO2)]) in patients who severely desaturate during exercise.MethodsWe compared patients receiving DODS oxygen and patients receiving continuous-flow oxygen, during both rest and iso-exercise.SettingThis study was conducted in the Pulmonary Rehabilitation Program at Mission Hospital, Regional Medical Center, Mission Viejo, California.SubjectsWe studied 10 patients with chronic lung disease and difficulty maintaining exercise S(pO2) with DODS. Nine patients had chronic obstructive pulmonary disease and one had restrictive lung disease. The group's (mean +/- SD) demographic and physiologic values included: age 67 +/- 7 y, forced expiratory volume in the first second 0.79 +/- 0.3 L, forced vital capacity 1.7 +/- 0.7 L, and S(pO2) 88%.InterventionsResting S(pO2) was measured during continuous oxygen flow and during DODS, at identical settings. S(pO2) was allowed to stabilize at each level before recording. During treadmill exercise at identical work loads we measured continuous flow and DODS S(pO2) at the same settings. If the DODS S(pO2) was less than during the equivalent continuous flow, the DODS setting was increased for another treadmill trial.ResultsAt rest the DODS was equivalent to continuous flow: S(pO2) was 93.7 +/- 2.1% with DODS and 93.8 +/- 1.9% with continuous flow. During exercise at corresponding settings DODS S(pO2) was 90.5 +/- 3.8% and continuous-flow S(pO2) was 93.1 +/- 3.1%. Six subjects had S(pO2) > 90%, with 4 of them achieving equivalency. At higher DODS settings S(pO2) became equivalent: 92.5 +/- 2.8%. The DODS oxygen-use efficiency advantage was 6.7-fold at rest and 5.6-fold during exercise, except with subjects who required a higher exercise DODS setting, with whom the DODS advantage was 4.3-fold.ConclusionsThe redesigned Oxymatic 401 DODS maintains adequate S(pO2) during rest and exercise, but some patients require the higher delivery settings. We recommend that all patients prescribed DODS undergo exercise evaluation with the prescribed DODS to ensure efficacy and determine the DODS settings required to maintain S(pO2) at the prescribed limits.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.