• Critical care medicine · Mar 1996

    Low measured auto-positive end-expiratory pressure during mechanical ventilation of patients with severe asthma: hidden auto-positive end-expiratory pressure.

    • J W Leatherman and S A Ravenscraft.
    • Department of Medicine, Hennepin County Medical Center, Minneapolis, MN 55415, USA.
    • Crit. Care Med. 1996 Mar 1;24(3):541-6.

    ObjectiveTo describe the occurrence of low measured auto-end-expiratory pressure (auto-PEEP) during mechanical ventilation of patients severe asthma.DesignObservational clinical study.SettingMedical intensive care unit of a university-affiliated county hospital.PatientsFour mechanically ventilated patients with severe asthma who had low measured auto-PEEP despite marked increase in both peak and plateau airway pressures.InterventionsNone.Measurements And Main ResultsPeak pressure, plateau pressure, and auto-PEEP were measured at an early time point, when airflow obstruction was most severe, and again at a later time after clinical improvement. Auto-PEEP was measured by the method of end-expiratory airway occlusion. From the early to the late point, there was a marked decrease in peak pressure (76 +/- 7 to 53 +/- 6 cm H2O; p<.001) and in plateau pressure (28 +/- 2 to 18 +/- 3 cm H2O; p<.001), but only minimal change in auto-PEEP (5 +/- 3 to 4 +/- 3 cm H2O). The difference between plateau pressure and auto-PEEP decreased between the early and late time points (23 +/- 1 to 14 +/- 1 cm H2O; p<.01), even though tidal volume was larger at the late time point. In three patients, low auto-PEEP and a large difference between plateau pressure and auto-PEEP was only seen after expiratory time was prolonged. In these three patients, prolongation of expiratory time resulted in a large decrease in measured auto-PEEP (14 +/- 4 to 5 +/- 4 cm H2O), but a much smaller change in plateau pressure (31 +/- 3 to 29 +/- 3 cm H2O).ConclusionsWe conclude that measured auto-PEEP may underestimate end-expiratory alveolar pressure in severe asthma, and that marked pulmonary hyperinflation may be present despite low measured auto-PEEP, especially at low respiratory rates. This phenomenon may be due to widespread airway closure that prevents accurate assessment of alveolar pressure at end-expiration.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.