-
Critical care medicine · Mar 1996
Low measured auto-positive end-expiratory pressure during mechanical ventilation of patients with severe asthma: hidden auto-positive end-expiratory pressure.
- J W Leatherman and S A Ravenscraft.
- Department of Medicine, Hennepin County Medical Center, Minneapolis, MN 55415, USA.
- Crit. Care Med. 1996 Mar 1;24(3):541-6.
ObjectiveTo describe the occurrence of low measured auto-end-expiratory pressure (auto-PEEP) during mechanical ventilation of patients severe asthma.DesignObservational clinical study.SettingMedical intensive care unit of a university-affiliated county hospital.PatientsFour mechanically ventilated patients with severe asthma who had low measured auto-PEEP despite marked increase in both peak and plateau airway pressures.InterventionsNone.Measurements And Main ResultsPeak pressure, plateau pressure, and auto-PEEP were measured at an early time point, when airflow obstruction was most severe, and again at a later time after clinical improvement. Auto-PEEP was measured by the method of end-expiratory airway occlusion. From the early to the late point, there was a marked decrease in peak pressure (76 +/- 7 to 53 +/- 6 cm H2O; p<.001) and in plateau pressure (28 +/- 2 to 18 +/- 3 cm H2O; p<.001), but only minimal change in auto-PEEP (5 +/- 3 to 4 +/- 3 cm H2O). The difference between plateau pressure and auto-PEEP decreased between the early and late time points (23 +/- 1 to 14 +/- 1 cm H2O; p<.01), even though tidal volume was larger at the late time point. In three patients, low auto-PEEP and a large difference between plateau pressure and auto-PEEP was only seen after expiratory time was prolonged. In these three patients, prolongation of expiratory time resulted in a large decrease in measured auto-PEEP (14 +/- 4 to 5 +/- 4 cm H2O), but a much smaller change in plateau pressure (31 +/- 3 to 29 +/- 3 cm H2O).ConclusionsWe conclude that measured auto-PEEP may underestimate end-expiratory alveolar pressure in severe asthma, and that marked pulmonary hyperinflation may be present despite low measured auto-PEEP, especially at low respiratory rates. This phenomenon may be due to widespread airway closure that prevents accurate assessment of alveolar pressure at end-expiration.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.