• J Anaesthesiol Clin Pharmacol · Jan 2013

    Comparison of clinical performance of the I-gel with LMA proseal.

    • Gaurav Chauhan, Pavan Nayar, Anita Seth, Kapil Gupta, Mamta Panwar, and Nidhi Agrawal.
    • Department of Anesthesia and Intensive Care, Safdarjang Hospital, New Delhi, India.
    • J Anaesthesiol Clin Pharmacol. 2013 Jan 1;29(1):56-60.

    AimTo compare insertion characteristics of 2 different supraglottic devices [I-gel and Proseal laryngeal mask airway (PLMA)] and to observe any associated complications.Study DesignThis prospective, randomized study was conducted in 80 patients [Group I - I-gel insertion (n = 40) and Group P - LMA Proseal insertion (n =40)] of ASA grades I/II, of either sex in the age group 18-65 years. Both groups were compared with respect to ease of insertion, insertion attempts, fiberoptic assessment, airway sealing pressure, ease of gastric tube placement, and other complications.Materials And MethodsAll patients were asked to fast overnight. Patients were given alprazolam 0.25 mg orally at 10 p.m. the night before surgery and again 2 hours prior to surgery with 1-2 sips of water. Glycopyrrolate 0.2 mg, metoclopramide 10 mg, and ranitidine 50 mg were administered intravenously to the patients 45 minutes prior to the surgery. Once adequate depth of anesthesia was achieved either of the 2 devices, selected using a random computerized table, was inserted by an experienced anesthesiologist. In group I, I-gel was inserted and in patients of group P, PLMA was inserted.Statistical AnalysisStudent t-test and Mann-Whitney test were employed to compare the means; for categorical variables, Chi-square test was used.ResultMean insertion time for the I-gel (11.12 ± 1.814 sec) was significantly lower than that of the PLMA (15.13 ± 2.91 sec) (P = 0.001). I-gel was easier to insert with a better anatomic fit. Mean airway sealing pressure in the PLMA group (29.55 ± 3.53 cm H2O) was significantly higher than in the I-gel group (26.73 ± 2.52 cm H2O; P = 0.001). Ease of gastric tube insertion was significantly higher in the I-gel group (P = 0.001). Incidence of blood staining of the device, sore throat and dysphagia were observed more in PLMA group. No other complications were observed in either of the groups.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…