• Proc. Natl. Acad. Sci. U.S.A. · Jun 2014

    Size-based molecular diagnostics using plasma DNA for noninvasive prenatal testing.

    • Stephanie C Y Yu, K C Allen Chan, Yama W L Zheng, Peiyong Jiang, Gary J W Liao, Hao Sun, Ranjit Akolekar, Tak Y Leung, Attie T J I Go, John M G van Vugt, Ryoko Minekawa, Cees B M Oudejans, Kypros H Nicolai... more des, Rossa W K Chiu, and Y M Dennis Lo. less
    • Centre for Research into Circulating Fetal Nucleic Acids, Li Ka Shing Institute of Health Sciences, The Chinese University of Hong Kong, Shatin, NT, Hong Kong SAR, China;Department of Chemical Pathology, T... more he Chinese University of Hong Kong, Prince of Wales Hospital, Shatin, NT, Hong Kong SAR, China; less
    • Proc. Natl. Acad. Sci. U.S.A. 2014 Jun 10;111(23):8583-8.

    AbstractNoninvasive prenatal testing using fetal DNA in maternal plasma is an actively researched area. The current generation of tests using massively parallel sequencing is based on counting plasma DNA sequences originating from different genomic regions. In this study, we explored a different approach that is based on the use of DNA fragment size as a diagnostic parameter. This approach is dependent on the fact that circulating fetal DNA molecules are generally shorter than the corresponding maternal DNA molecules. First, we performed plasma DNA size analysis using paired-end massively parallel sequencing and microchip-based capillary electrophoresis. We demonstrated that the fetal DNA fraction in maternal plasma could be deduced from the overall size distribution of maternal plasma DNA. The fetal DNA fraction is a critical parameter affecting the accuracy of noninvasive prenatal testing using maternal plasma DNA. Second, we showed that fetal chromosomal aneuploidy could be detected by observing an aberrant proportion of short fragments from an aneuploid chromosome in the paired-end sequencing data. Using this approach, we detected fetal trisomy 21 and trisomy 18 with 100% sensitivity (T21: 36/36; T18: 27/27) and 100% specificity (non-T21: 88/88; non-T18: 97/97). For trisomy 13, the sensitivity and specificity were 95.2% (20/21) and 99% (102/103), respectively. For monosomy X, the sensitivity and specificity were both 100% (10/10 and 8/8). Thus, this study establishes the principle of size-based molecular diagnostics using plasma DNA. This approach has potential applications beyond noninvasive prenatal testing to areas such as oncology and transplantation monitoring.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        

    hide…