    The development of feedback monitoring device for CPR.

    • Yeong-Tak Song and Youngjoon Chee.
    • Department of Bioengineering, University of California, San Diego, La Jolla, CA, USA. tagy25@naver.com
    • Conf Proc IEEE Eng Med Biol Soc. 2011 Jan 1;2011:3294-7.

    AbstractCPR (Cardio-Pulmonary Resuscitation) is known as the most basic aid in emergency situations. For successful CPR, the chest compression depth, cycle, and compressing point are important factors. In I.C.U.'s (Intensive Care Unit) and E.R.'s (Emergency Room), monitoring devices are used to monitor the chest compressions correctly. These devices use accelerometers or pressure sensors. Because the mattress under the patient compresses together, these devices overestimate the compression depth. To overcome this problem, two accelerometers are used in this study, one is on the chest, and the other is between the back of the patient and the mattress. The measurement setup and algorithm to estimate the compression depth are explained. According to the experiment with the mannequin, when CPR is done on a mattress, the actual compression depth was 43.7 mm (S.D. 1.93 mm). The estimated compression depth was 61.4mm (S.D. 1.87 mm) when using an acceleration sensor. This includes the depth of compression of the mattress. When we use two acceleration sensors, estimated compression depth is 44.6mm (S.D. 1.59 mm), which is similar to the actual compression depth. In conclusion, the dual accelerometer gives more accurate estimated compression depth than conventional devices.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.