• Br J Anaesth · Oct 2011

    Uncalibrated arterial pressure waveform analysis for cardiac output monitoring is biased by low peripheral resistance in patients with intracranial haemorrhage.

    • E K Junttila, J K Koskenkari, P P Ohtonen, and T I Ala-Kokko.
    • Division of Intensive Care, Department of Anesthesiology, Oulu University Hospital, PO Box 21, FIN-90029 OUH, Oulu, Finland. eija.junttila@oulu.fi
    • Br J Anaesth. 2011 Oct 1;107(4):581-6.

    BackgroundCardiac output (CO) monitoring by uncalibrated arterial pressure waveform analysis (APCO) using the FloTrac/Vigileo™ is feasible in patients with intracranial haemorrhage, but the results of validation studies are contradictory. The aim of the present study was to analyse the clinical agreement between the intermittent bolus thermodilution technique (TDCO) and APCO in patients with non-traumatic intracranial haemorrhage.MethodsThis was a prospective observational clinical study in a university level intensive care unit. We studied patients who underwent CO monitoring according to clinical indications using TDCO. Simultaneously, APCO was applied using the radial arterial pressure curve. The difference in CO values measured by APCO with a mid-chest calibration level was compared with a calibration level at the angle of the eye.ResultsA total of 407 data pairs from 16 patients were obtained. The mean CO(TDCO) was 7.6 litre min(-1) and CO(APCO) was 6.0 litre min(-1), with a bias corrected for repeated measures of 1.5 litre min(-1) and 95% limits of agreement of -2.4 to 5.4 litre min(-1). The percentage error was 58%. The increasing bias correlated with low peripheral resistance (ρ=-0.53, P=0.036). The calibration level at the patient's eye angle did not affect CO values (median bias 0 litre min(-1) with 25th-75th percentile -0.1 to 0.2 litre min(-1)).ConclusionsThe second generation of FloTrac(®)/Vigileo(®) monitoring system underestimates the TDCO in patients with non-traumatic intracranial haemorrhage. The bias correlates with measured systemic vascular resistance. The upper calibration level does not affect the results.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.