• Blood pressure monitoring · Oct 2011

    Application of Nexfin noninvasive beat-to-beat arterial blood pressure monitoring in autonomic function testing.

    • Laura M Sipkens, Kaij Treskes, Karin Ariese-Beldman, Derk P Veerman, and Christa Boer.
    • Department of Anesthesiology, Institute for Cardiovascular Research, VU University Medical Center, Amsterdam, The Netherlands.
    • Blood Press Monit. 2011 Oct 1;16(5):246-51.

    ObjectiveEvaluation of autonomic function responses is increasingly important for risk prediction and hemodynamic evaluation in the ambulant and perioperative setting, but requires a noninvasive arterial blood pressure measurement device. This study describes whether a novel noninvasive beat-to-beat arterial blood pressure measurement device (Nexfin HD) is able to reproducibly reflect autonomic function responses in healthy volunteers.MethodsNoninvasive beat-to-beat arterial blood pressure measurements (Nexfin HD) were performed in 20 healthy men of 22 ± 3 years. Measurements were performed during supine steady state, controlled breathing (0.125 Hz), passive leg raising, a controlled Valsalva maneuver, and a quick stand test. Finally, relative changes in pulse pressure during autonomic function testing and the test-retest reproducibility were determined.ResultsAutonomic function tests induced beat-to-beat arterial blood pressure changes that were accurately monitored by the Nexfin device. The intraclass correlation coefficients for systolic and diastolic arterial blood pressure measurements during supine steady state were agreeable [0.91 (0.82-0.96) and 0.84 (0.69-0.93), respectively]. The reproducibility of blood pressure changes during controlled breathing, passive leg raising, and Valsalva maneuver averaged 0.92 (0.82-0.96), 0.76 (0.50-0.90), and 0.94 (0.89-0.97), respectively. The reproducibility of the pulse pressure variation (PPV) as calculated from controlled breathing-induced changes in the arterial blood pressure (13 ± 5%) was high [0.96 (0.93-0.98)].ConclusionThis study shows that noninvasive beat-to-beat Nexfin HD arterial blood pressure measurements reproducibly reflect autonomic function responses in healthy volunteers.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…