-
J Clin Monit Comput · Apr 2002
Automated evaluation of functional residual capacity by oxygen washout.
- Wolfgang Eichler, Jan Schumacher, Angela Roth-Isigkeit, Jörg Braun, Hermann Kuppe, and Karl-Friedrich Klotz.
- Department of Anesthesiology, Medical University of Luebeck, Germany. eichler@medinf.mu-luebeck.de
- J Clin Monit Comput. 2002 Apr 1; 17 (3-4): 195-201.
ObjectiveMeasurement of functional residual capacity (FRC) is of considerable interest for monitoring ventilated patients in ICUs. However, the lack of instruments that can be used in the clinical setting has so far impeded the routine application of this measurement. It was the aim of our study to evaluate the accuracy and the reproducibility of a simplified oxygen washout technique (FRC[O2]).Materials And MethodsFor the evaluation of FRC[O2J, gas flow, CO2 and O2 concentrations were determined by the flow probe of an ICU ventilator, a mainstream capnometer and O2 analyser. In 30 volunteers FRC[O2] as measured during spontaneous breathing was compared to: 1. Helium dilution technique (FRC[He], n = 21), 2. Body plethysmography (FRC[bp], n = 9). In n = 7 male patients FRC[O2] was repeatedly evaluated during mechanical ventilation and compared to the preoperative FRC[bp].ResultsFRC[O2J corresponded well with FRC[He] (range: 1.9 to 6.0 l, bias of FRC[O2]: 0.53 l (95% CI 0.24 l to 0.82 l)) and FRC[bp] (range: 2.1 to 4.3 l, bias of FRC[O2] 0.03 l (95% CI -0.30 l to 0.37 l)). The mean of the repeated FRC[O2]-measurements (basic range: 1.3 to 3.6 l) during mechanical ventilation with unchanged ventilator settings stayed unchanged. The within subject-between error ranged from 0.1 to 0.4 l (mean = 0.23 1). Mean FRC[O2] during mechanical ventilation decreased to 66.6 percent of the preoperative mean FRC[bp].ConclusionsThe automated oxygen washout technique is a simple method to measure FRC in the ICU patient.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.