Comparative Study
Positive end-expiratory pressure increases the right-to-left shunt in mechanically ventilated patients with patent foramen ovale.
- B Cujec, P Polasek, I Mayers, and D Johnson.
- Royal University Hospital, University of Saskatchewan, Saskatoon, Canada.
- Ann. Intern. Med. 1993 Nov 1;119(9):887-94.
ObjectiveTo determine the effect of the presence of a patent foramen ovale on the right-to-left shunt in patients with respiratory failure who receive positive end-expiratory pressure (PEEP).DesignConvenience sample with randomized application of PEEP.SettingGeneral intensive care unit of a university teaching hospital.PatientsA total of 46 mechanically ventilated patients with respiratory failure requiring an inspired oxygen concentration of at least 50% and a PEEP of at least 5 cm of H2O.InterventionRandomized application of PEEP (0 and 10 cm of H2O).MeasurementsA patent foramen ovale was detected by saline contrast transesophageal echocardiography. The alveolar-to-arterial oxygen difference and the right-to-left shunt were calculated from arterial and venous blood gas sampling.ResultsIn patients without a patent foramen ovale (n = 39), the alveolar-to-arterial oxygen difference and the shunt fraction decreased (-50 mm Hg [95% CI, -21 to -67] and -0.05 [CI, -0.03 to -0.07], respectively) after adding PEEP (10 cm of H2O). In patients with a patent foramen ovale (n = 7), minimal changes were noted in the alveolar-to-arterial oxygen difference (4 mm Hg, P > 0.2), but the shunt fraction increased (0.05, CI, 0 to 0.09). Adding PEEP (10 cm of H2O) increased the shunt fraction in 6 of 7 (86%) patients with a patent foramen ovale, whereas the shunt increased in only 7 of 39 (18%) patients without a patent foramen ovale (P < 0.007).ConclusionsA patent foramen ovale was found in 7 of 46 patients (15%; CI, 6% to 29%) with acute respiratory failure. This condition is a common cause of lack of improvement in oxygenation with the addition of PEEP in the mechanically ventilated patient. In patients with a patent foramen ovale, the right-to-left shunt is usually increased by using PEEP.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.