• Am. J. Physiol. · Feb 1990

    Pharyngeal and upper esophageal sphincter manometry in humans.

    • J A Castell, C B Dalton, and D O Castell.
    • Gastroenterology Section, Bowman Gray School of Medicine, Wake Forest University, Winston-Salem, North Carolina 27103.
    • Am. J. Physiol. 1990 Feb 1;258(2 Pt 1):G173-8.

    AbstractManometric studies of pharyngeal-upper esophageal sphincter (UES) coordination during swallowing have proven difficult. Asymmetry of the UES makes pressure measurements with a single, unoriented transducer suspect. Perfused systems lack the necessary response rate for measuring peak pharyngeal contraction pressures. Precise quantification of the coordination of pharyngeal contractions and UES relaxations during swallowing is difficult because of rapid pressure changes. We tested a modified solid-state transducer that measures pressures over 360 degrees. This transducer was placed in the proximal UES with a second, single transducer 5 cm proximal. Data were collected and analyzed with an Apple IIe microcomputer. A computer program was developed to measure nine timing sequences, UES resting pressure, nadir of UES relaxation, and pharyngeal contraction pressures. We studied 21 volunteers with six swallows each for dry, 5, 10, and 20 ml of water. Dry swallows differed significantly (P less than 0.05) from wet (5 ml). All timing sequences became progressively longer with increasing bolus size. Residual pressures were unchanged. Timing sequences were also measured for wet (5 ml) and dry swallows in seven volunteers using a Dent sleeve and single perfused orifice in the UES; no differences were seen.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.