• Ann Fr Anesth Reanim · Jan 1986

    [French survey on anesthesia systems and peroperative respiratory monitoring equipment].

    • J L Bourgain, J Duranteau, H Deriaz, and Y Noviant.
    • Ann Fr Anesth Reanim. 1986 Jan 1;5(5):518-23.

    AbstractA national inquiry has been carried out in France. It concerned the anaesthetic systems and respiratory monitoring equipment in use at the moment, as well as that wished for. The equipment in use was very stereotyped: an open system with a respirator, for the most volumetric, and with a safety O2/N2O mixer. Monitoring is carried out with the pressure gauges and the measure of expiratory volume; only two thirds of the equipment had an alarm. The O2 and CO2 analysers were little used. Expired CO2 monitoring was only carried out in teaching hospitals and in big centres. Apart from this, the equipment was independent of the hospital and the type of surgery carried out. As for anaesthetic systems, 53% of centres would like obtain open systems, 15% closed systems; 32% did not answer. This increase in number of closed systems is not significant. However, a very strong wish for respirators with flow rate control and safety O2/N2O mixers was observed, whilst the safety parameters of these mixers were open to discussion. Respiratory monitoring was not just confined to the mechanical aspects, as 65% of centres wished to monitor FIO2. The big centres and the teaching hospitals were interested by the expiratory CO2 monitoring. This inquiry showed the interest in respiratory safety in operating theatres. Further studies should confirm or not the increasing interest in closed systems.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…