- Pamela J Angle, Jean E Kronberg, Dorothy E Thompson, James Duffin, Peter Faure, Shan Balasubramaniam, John Paul Szalai, and Susan Cromwell.
- Department of Anesthesia, Women's College Hospital Campus, Sunnybrook and Women's College Hospital, University of Toronto, Ontario, Canada. pamela.angle@sw.ca
- Anesthesiology. 2004 Jun 1;100(6):1491-6.
BackgroundFactors contributing to subarachnoid catheter passage after epidural placement are not well understood. This study explored mechanisms that might explain its occurrence.MethodsHuman cadaveric dura was mounted on a model and pressurized to physiologic levels. In a standardized fashion, a 20-gauge Portex three-port, closed end (nonflexible) tip catheter was passed through an epidural needle mounted on a micromanipulator at a 90 degree angle, attempting to penetrate dura with the catheter. Attempts then followed with a 19-gauge Arrow Flex Tip Plus single-port catheter. Subarachnoid catheter passage was compared in (1) intact dura, (2) clinically occult versus obvious epidural needle punctures, and (3) single 25-gauge Whitacre spinal needle punctures after combined spinal-epidural placement.ResultsNeither catheter penetrated intact dura: Portex, 0 of 300 attempts (0.0000; 95% confidence interval [CI]: 0.0000, 0.0158); Arrow, 0 of 300 attempts (0.0000; 95% CI: 0.0000, 0.0158). In clinically occult epidural needle punctures, the 20-gauge Portex catheter penetrated 1 of 3 specimens in 1 of 14 attempts (0.0714; 95% CI: 0.0021, 0.3583). The 19-gauge Arrow did not pass (0 of 15 attempts, 0.0000; 95% CI: 0.0000, 0.2535). In clinically obvious epidural needle punctures, the Portex passed in 6 of 33 attempts (0.1818; 95% CI: 0.0760, 0.3608) and the Arrow passed in 1 of 35 attempts (0.0286; 95% CI: 0.0012, 0.1662). Neither catheter passed through a single 25-gauge spinal needle puncture after an uncomplicated combined spinal-epidural: Portex, 0 of 90 attempts (0.0000; 95% CI: 0.0000, 0.0510); Arrow, 0 of 90 attempts (0.0000; 95% CI: 0.0000, 0.0510).ConclusionsCatheter passage is unlikely in the presence of intact dura or after an uncomplicated combined spinal-epidural. Unintentional subarachnoid passage suggests dural damage with the epidural needle.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.