• Anesthesiology · Jun 2004

    Epidural catheter penetration of human dural tissue: in vitro investigation.

    • Pamela J Angle, Jean E Kronberg, Dorothy E Thompson, James Duffin, Peter Faure, Shan Balasubramaniam, John Paul Szalai, and Susan Cromwell.
    • Department of Anesthesia, Women's College Hospital Campus, Sunnybrook and Women's College Hospital, University of Toronto, Ontario, Canada. pamela.angle@sw.ca
    • Anesthesiology. 2004 Jun 1;100(6):1491-6.

    BackgroundFactors contributing to subarachnoid catheter passage after epidural placement are not well understood. This study explored mechanisms that might explain its occurrence.MethodsHuman cadaveric dura was mounted on a model and pressurized to physiologic levels. In a standardized fashion, a 20-gauge Portex three-port, closed end (nonflexible) tip catheter was passed through an epidural needle mounted on a micromanipulator at a 90 degree angle, attempting to penetrate dura with the catheter. Attempts then followed with a 19-gauge Arrow Flex Tip Plus single-port catheter. Subarachnoid catheter passage was compared in (1) intact dura, (2) clinically occult versus obvious epidural needle punctures, and (3) single 25-gauge Whitacre spinal needle punctures after combined spinal-epidural placement.ResultsNeither catheter penetrated intact dura: Portex, 0 of 300 attempts (0.0000; 95% confidence interval [CI]: 0.0000, 0.0158); Arrow, 0 of 300 attempts (0.0000; 95% CI: 0.0000, 0.0158). In clinically occult epidural needle punctures, the 20-gauge Portex catheter penetrated 1 of 3 specimens in 1 of 14 attempts (0.0714; 95% CI: 0.0021, 0.3583). The 19-gauge Arrow did not pass (0 of 15 attempts, 0.0000; 95% CI: 0.0000, 0.2535). In clinically obvious epidural needle punctures, the Portex passed in 6 of 33 attempts (0.1818; 95% CI: 0.0760, 0.3608) and the Arrow passed in 1 of 35 attempts (0.0286; 95% CI: 0.0012, 0.1662). Neither catheter passed through a single 25-gauge spinal needle puncture after an uncomplicated combined spinal-epidural: Portex, 0 of 90 attempts (0.0000; 95% CI: 0.0000, 0.0510); Arrow, 0 of 90 attempts (0.0000; 95% CI: 0.0000, 0.0510).ConclusionsCatheter passage is unlikely in the presence of intact dura or after an uncomplicated combined spinal-epidural. Unintentional subarachnoid passage suggests dural damage with the epidural needle.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.