• Resp Care · Jul 2011

    Chester step test in patients with COPD: reliability and correlation with pulmonary function test results.

    • Anderson Alves de Camargo, Tatiana Justino, Carlos Henrique Silva de Andrade, Carla Malaguti, and Simone Dal Corso.
    • School of Physiotherapy, Department of Health, Rehabilitation Science Master's Program, Nove de Julho University, Bairro Água Branca, São Paulo, Brazil.
    • Resp Care. 2011 Jul 1;56(7):995-1001.

    BackgroundThe 5-stage Chester step test assesses aerobic capacity in healthy subjects. It has not been tested in patients with COPD.ObjectiveTo determine the reliability of the Chester step test in patients with COPD and correlation with pulmonary function test and exercise test results.MethodsThirty-two patients (mean ± SD FEV(1) 46 ± 15% of predicted) undertook 2 Chester step tests and two 6-min walk tests, on different days, in random order. A subgroup of 11 patients performed incremental cycle ergometry.ResultsThirty-one patients performed stage 1 of the Chester step test. Nineteen patients performed stage 2 of the Chester step test. The number of steps was highly reproducible: 66 ± 41 steps vs 68 ± 41 steps. There was no difference in heart rate or S(pO(2)) between the 2 Chester step tests at the peak of exercise or at the end of each stage. There was a significant correlation between number of steps and FEV(1) (r = 0.43, P = .02), and 6-min walk distance (r = 0.60, P = .001). Heart rate increased according to advanced stages of the Chester step test, up to 81 ± 13% of predicted. There was a significant correlation between number of steps and peak heart rate (r = 0.55, P = .001). In the 11 patients who performed the incremental cycling test there was a significant correlation between number of steps and peak work load (r = 0.69, P = .02). In the 6 patients in whom oxygen uptake could be estimated from the Chester step test, oxygen uptake was higher than that measured at the peak of the cycling test (30.8 ± 5.1 mL/kg/min vs 17.4 ± 4.5 mL/kg/min, respectively, P = .001).ConclusionsDespite being highly reproducible, the Chester step test had a very short duration in patients with COPD. The number of steps incremented in each stage seems to be too large for these patients. An adaptation of the Chester step test should be considered for patients with COPD.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…