• Aust Crit Care · Feb 2007

    Comparative Study

    Comparison of dynamic measurements of pulse contour with pulsed heat continuous cardiac output in postoperative cardiac surgical patients.

    • Martin Boyle, John Lawrence, Andrew Belessis, Margherita Murgo, and Yahya Shehabi.
    • Intensive Care, Prince of Wales Hospital, Barker St., Randwick, NSW 2031, Australia. martin.boyle@sesiahs.health.nsw.gov.au
    • Aust Crit Care. 2007 Feb 1;20(1):27-32.

    AbstractCardiac output (CO) can be measured using bolus thermodilution via a pulmonary artery catheter (PAC) and as continuous cardiac output (CCO), using pulsed heat thermoditution. Pulse contour cardiac output (PCCO) measures continuous CO by analysis of the arterial waveform after calibration with thermodilution CO. The Pulsion Medical Systems (PiCCO system) achieves this by transpulmonary aortic thermodilution (TDtpa). There is uncertainty regarding the agreement between TDtpa, CCO, and PCCO CO measurements in situations of rapid haemodynamic changes. We studied the agreement of the measures by comparing digital recordings of cardiac index (CI) determined by PCCO and CCO (PCCI and CCI, respectively) made during periods of haemodynamic instability. After ethics committee approval we studied four post-coronary artery bypass graft patients, in the immediate postoperative period. Each patient had a 7.5F CCO catheter (Edwards Lifesciences) and a 5F, 20cm PCCO femoral artery catheter. Digital recordings were obtained for the first 12-18 postoperative hours. Six epochs of instability were identified in the first two to three postoperative hours, and at the commencement of inotropic or vasoactive drugs. Notable features, despite frequent PCCO calibrations, were the marked difference of PCCI compared to CCI. In contradistinction, they tracked very closely during a period of stability. Limitations of both methods were noted. Whilst PCCO responded to rapid change, it developed significant error during haemodynmamic instability and requires frequent recalibration. CCO on the other hand has a considerable time lag in responding to changes in CO. The way a monitor measures CO must be taken into account when using the data in clinical management.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…