• Resp Care · Jan 2007

    Setting positive end-expiratory pressure during jet ventilation to replicate the mean airway pressure of oscillatory ventilation.

    • Andora L Bass, Michael A Gentile, John P Heinz, Damian M Craig, Donna S Hamel, and Ira M Cheifetz.
    • Pediatric Critical Care, East Carolina University, Brody School of Medicine, 600 Moye Boulevard, Greenville NC 27834, USA. bassa@ecu.edu
    • Resp Care. 2007 Jan 1;52(1):50-5.

    BackgroundHigh-frequency ventilation can be delivered with either oscillatory ventilation (HFOV) or jet ventilation (HFJV). Traditional clinician biases may limit the range of function of these important ventilation modes. We hypothesized that (1) the jet ventilator can be an accurate monitor of mean airway pressure (P (aw)) during HFOV, and (2) a mathematical relationship can be used to determine the positive end-expiratory pressure (PEEP) setting required for HFJV to reproduce the P (aw) of HFOV.MethodsIn phase 1 of our experiment, we used a differential pressure pneumotachometer and a jet adapter in-line between an oscillator circuit and a pediatric lung model to measure P (aw), PEEP, and peak inspiratory pressure (PIP). Thirty-six HFOV setting combinations were studied, in random order. We analyzed the correlation between the pneumotachometer and HFJV measurements. In phase 2 we used the jet as the monitoring device during each of the same 36 combinations of HFOV settings, and recorded P (aw), PIP, and DeltaP. Then, for each combination of settings, the jet ventilator was placed in-line with a conventional ventilator and was set at the same rate and PIP as was monitored during HFOV. To determine the appropriate PEEP setting, we calculated the P (aw) contributed by the PIP, respiratory rate, and inspiratory time set for HFJV, and subtracted this from the goal P (aw). This value was the PEEP predicted for HFJV to match the HFOV P (aw).ResultsThe correlation coefficient between the pneumotachometer and HFJV measurements was r = 0.99 (mean difference 0.62 +/- 0.30 cm H(2)O, p < 0.001). The predicted and actual PEEP required were highly correlated (r = 0.99, p < 0.001). The mean difference in these values is not statistically significantly different from zero (mean difference 0.25 +/- 1.02 cm H(2)O, p > 0.15).ConclusionsHFJV is an accurate monitor during HFOV. These measurements can be used to calculate the predicted PEEP necessary to match P (aw) on the 2 ventilators. Replicating the P (aw) with adequate PEEP on HFJV may help simplify transitioning between ventilators when clinically indicated.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.