• Ann Fr Anesth Reanim · Jul 2010

    Continuous non-invasive arterial pressure measurement: evaluation of CNAP device during vascular surgery.

    • M Biais, L Vidil, S Roullet, F Masson, A Quinart, P Revel, and F Sztark.
    • Service d'anesthésie réanimation 1, hôpital Pellegrin, CHU de Bordeaux, place Amélie-Raba-Léon, 33076 Bordeaux cedex, France. matthieu.biais@chu-bordeaux.fr
    • Ann Fr Anesth Reanim. 2010 Jul 1; 29 (7-8): 530-5.

    ObjectiveStandard non-invasive blood pressure (BP) monitoring is an intermittent, discontinuous procedure. Beat-to-beat BP monitoring requires invasive measurement via an arterial catheter and may be associated with serious complications. The Infinity CNAP SmartPod (Dräger Medical AG & Co. KG, Lübeck, Germany) has recently been proposed for non-invasive continuous beat-to-beat BP measurements. The present study was designed to compare BP obtained with the CNAP and with an invasive method in the operating room.Study DesignProspective study.Patients And MethodsTwenty-five patients undergoing major vascular surgery were included. Systolic, mean and diastolic BP were monitored invasively (SAP, MAP and DAP respectively) and not invasively using the CNAP (CNAP-S, CNAP-M and CNAP-D respectively). Measurements were performed intraoperatively every minute during 1 hour.ResultsOne thousand and five hundred pairs of simultaneous CNAP and invasive BP measurements were obtained and 148 were eliminated. The range of BP measurements was 63-205 mmHg for SAP and 57-187 mmHg for CNAP-S, 38-143 mmHg for MAP and 43-142 mmHg for CNAP-M, 29-126 mmHg for DAP and 33-121 mmHg for CNAP-D. Bias and 95% limit of agreement between CNAP and invasive BP measurements were respectively 7.2 and -17.7 to 32.2 mmHg for SAP, -1.8 and -22.0 to 18.3 mmHg for MAP, and -7.5 and -27.3 to 12.4 mmHg for DAP. The percentage of CNAP measurements with a bias <10% with the arterial line was 69%, 86% and 91% for systolic, diastolic and mean pressures, respectively.ConclusionDespite low accuracy for SAP and DAP measurements, CNAP system seems more accurate for MAP measurement in patients undergoing vascular surgery.Copyright 2010 Elsevier Masson SAS. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.