• J Trauma Acute Care Surg · Apr 2012

    Determination of efficacy of novel modified chitosan sponge dressing in a lethal arterial injury model in swine.

    • Gerard P De Castro, Matthew B Dowling, Michael Kilbourne, Kaspar Keledjian, Ian R Driscoll, Srinivasa R Raghavan, John R Hess, Thomas M Scalea, and Grant V Bochicchio.
    • R Adams Cowley Shock Trauma Center, University of Maryland School of Medicine, Baltimore, Maryland 21201, USA.
    • J Trauma Acute Care Surg. 2012 Apr 1;72(4):899-907.

    BackgroundChitosan is a functional biopolymer that has been widely used as a hemostat. Recently, its efficacy has been questioned due to clinical failures as a result of poor adhesiveness. The purpose of this study was to compare, in a severe groin injury model in swine, the hemostatic properties of an unmodified standard chitosan sponge with standard gauze dressing and a novel hydrophobically modified (hm) chitosan sponge. Previous studies have demonstrated that hm-chitosan provides greatly enhanced cellular adhesion and hemostatic effect via noncovalent insertion of hydrophobic pendant groups into cell membranes.MethodsTwenty-four Yorkshire swine were randomized to receive hm-chitosan (n = 8), unmodified chitosan (n = 8), or standard Accu-Sorb gauze dressing (n = 8) for hemostatic control. A complex groin injury involving arterial puncture (4.4-mm punch) of the femoral artery was made after splenectomy. After 30 seconds of uncontrolled hemorrhage, the randomized dressing was applied and compression was held for 3 minutes. Fluid resuscitation was initiated to achieve and maintain the baseline mean arterial pressure and the wound was inspected for bleeding. Failure of hemostasis was defined as pooling of blood outside the wound. Animals were then monitored for 180 minutes and surviving animals were killed.ResultsBlood loss before treatment was similar between groups (p < 0.1). Compared with the hm-chitosan sponge group, which had no failures, the unmodified chitosan sponge group and the standard gauze group each had eight failures over the 180-minute observation period. For the unmodified chitosan sponge failures, six of which provided initial hemostasis, secondary rebleeding was observed 44 minutes ± 28 minutes after application. Standard gauze provided no initial hemostasis after the 3-minute compression interval.ConclusionsHm-chitosan is superior to unmodified chitosan sponges (p < 0.001) or standard gauze for controlling bleeding from a lethal arterial injury. The hm-chitosan technology may provide an advantage over native chitosan-based dressings for control of active hemorrhage.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…