-
- Luis A Gaitini, Sonia J Vaida, Somri Mostafa, Boris Yanovski, Bruce Ben-David, and Jonathan L Benumof.
- Department of Anesthesiology, B'nai Zion Medical Center, Haifa 31048, Israel. l.gaitini@b-zion.org.il
- J Clin Anesth. 2005 Feb 1;17(1):26-9.
Study ObjectiveTo measure resistance of the Combitube, a supraglottic ventilatory device used in the management of the patients with difficult airways, and its influence on delivered ventilatory pressures.DesignProspective study.SettingUniversity-affiliated hospital.PatientsA total of 20 patients with ASA status I or II who were scheduled for elective knee arthroscopy.Interventions(Part 2 of the study) After induction of general anesthesia and insertion of the Combitube, mechanical ventilation was initiated. Airway pressures were measured using fluid-filled pressure lines at the Y-piece (P(Y-piece)) of the breathing system and in the oropharynx (P(oropharynx)) at a position 2 cm beyond the second proximal anterior hole of the Combitube. These pressures were simultaneously recorded and the pressure curves were compared.Measurements(Part 1 of the study) Resistance of the esophageal and the tracheal lumen of the 37-F Combitube and standard endotracheal tubes (with internal diameters of 6, 7, and 8 mm) was compared ex vivo with a Datex AS/3 monitor. Ventilation conditions were kept constant at a tidal volume of 0.5 L, frequency of 10 breaths per minute, and ramp flow waveform and peak flow of 1 L/s.Main ResultsResistance of standard endotracheal tubes was inversely proportional to their diameters (16, 11, and 7 cm H(2)O/L per second for the tubes with internal diameters of 6, 7, and 8 mm, respectively). The resistance of the Combitube's tracheal lumen was 12 cm H(2)O/L per second. There was a significant difference in peak respiratory pressures between P(Y-piece) and P(oropharynx) (40 +/- 5 and 23 +/- 5 cm H(2)O, respectively).ConclusionsThe Combitube has significant airflow resistance that should be considered when patients are mechanically ventilated because the delivered oropharyngeal pressure is significantly lower than the pressure measured at the anesthesia breathing system.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.