Comparison of different flow-reducing bag-valve ventilation devices regarding respiratory mechanics and gastric inflation in an unprotected airway model.
- Fabienne C Rabus, Heinz-Theo Luebbers, Klaus W Graetz, and Till S Mutzbauer.
- Department of Craniomaxillofacial Surgery, University of Zurich Dental Center, Plattenstrasse 15, CH-8032 Zurich, Switzerland.
- Resuscitation. 2008 Aug 1;78(2):224-9.
ObjectiveGastric inflation (GI) is a significant issue when ventilation is performed on unprotected airways.DesignExperimental analysis on the respiratory effects of hose extended bag-valve ventilation devices designed to reduce inspiratory pressure and flow.SettingLaboratory with lung/oesophageal sphincter simulator and pressure-flow-volume analyser. Lung compliance: 300ml/kPa, airway resistance: 0.5kPa/l/s. Lower oesophageal sphincter pressure (LOSP): 0.5kPa.InterventionsBag-valve ventilation of lung simulator. Twelve academic dental staff members used four devices: Ambu Mark III attached to either a reservoir bag (R) or a pressure relief valve (SV), SMART BAG (SB), and Easy Grip (EG) as control.ResultsAfter Bonferroni correction (p-level of significance 0.0083) for multiple comparisons, no evidence of difference between inspiratory tidal volumes (TVIN) administered by use of R (median 137ml) and SB (149ml) was found. Differences in TVIN were only detected between R and SV (188ml) (p=0.002). Only a trend towards TVIN differences between SB and R in comparison to EG (195ml) was found (p=0.009). Distributions of peak pressures differed when R (median 0.7kPa) and SV (1.0kPa) (p=0.006) or SB (0.7kPa) and SV (p=0.002) were compared. Peak inspiratory flow rates differed between EG (median 59l/min) and R (32l/min) as well as SB (42l/min) and between SB and SV (50l/min) (all with p=0.001). GI was lowest by use of R (median 103ml) compared to all other devices (EG: 518ml, SV: 394ml, SB: 271ml) (p=0.001). The areas under the pressure/flow over time curves were larger during SB compared to R ventilation. Mean airway pressures were significantly lower by use of R (0.1kPa) compared to SB (0.3kPa) (p<0.008).ConclusionLowering GI by pressure-flow reduction may result in lower TV depending on the device used. Lowest GI resulted from R ventilation. This may be explained by the specific pressure/time or flow/time patterns achieved by use of this device.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.