-
Clin Physiol Funct Imaging · Jul 2009
Inert gas rebreathing: the effect of haemoglobin based pulmonary shunt flow correction on the accuracy of cardiac output measurements in clinical practice.
- F Trinkmann, T Papavassiliu, F Kraus, H Leweling, Stefan O Schoenberg, M Borggrefe, J J Kaden, and J Saur.
- First Department of Medicine - Cardiology, Angiology, Pneumology, Intensive Care, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany.
- Clin Physiol Funct Imaging. 2009 Jul 1;29(4):255-62.
BackgroundCardiac output (CO) is an important cardiac parameter, however its determination is difficult in clinical routine. Non-invasive inert gas rebreathing (IGR) measurements yielded promising results in recent studies. It directly measures pulmonary blood flow (PBF) which equals CO in absence of significant pulmonary shunt flow (Q(S)). A reliable shunt correction requiring the haemoglobin concentration (c(Hb)) as only value to be entered manually has been implemented. Therefore, the aim of the study was to evaluate the effect of various approaches to Q(S) correction on the accuracy of IGR.MethodsCardiac output determined by cardiac magnetic resonance imaging (CMR) served as reference values. The data was analysed in four groups: PBF without correcting for Q(S) (group A), shunt correction using the patients' individual c(Hb) values (group B), a fixed standard c(Hb) of 14.0 g dl(-1) (group C) and a gender-adapted standard c(Hb) for male (15.0 g dl(-1)) and female (13.5 g dl(-1)) probands each (group D).Results147 patients were analysed. Mean CO(CMR) was 5.2 +/- 1.4 l min(-1), mean CO(IGR) was 4.8 +/- 1.3 l min(-1) in group A, 5.1 +/- 1.3 in group B, 5.1 +/- 1.3 l min(-1) in group C and 5.1 +/- 1.4 l min(-1) in group D. The accuracy in group A (mean bias 0.5 +/- 1.1 l min(-1)) was significantly lower as compared to groups B, C and D (0.1 +/- 1.1 l min(-1); P<0.01).ConclusionIGR allows a reliable non-invasive determination of CO. Since PBF significantly increased the measurement bias, shunt correction should always be applied. A fixed c(Hb) of 14.0 g dl(-1) can be used for both genders if the exact c(Hb) value is not known. Nevertheless, the individual value should be used if any possible.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.