Clinical physiology and functional imaging
-
Clin Physiol Funct Imaging · Jul 2009
Randomized Controlled TrialA preliminary investigation into the effect of coffee on hypolagesia associated with transcutaneous electrical nerve stimulation.
Transcutaneous electrical nerve stimulation (TENS) is a non-invasive, inexpensive analgesic technique used to relieve pain. It has been suggested that caffeine, an adenosine antagonist, may interfere with TENS action. This double-blind controlled pilot study investigated the effect of coffee on response to TENS in healthy human participants experiencing experimentally induced pain. ⋯ The statistical analysis modelled the responses for the coffee and decaffeinated coffee conditions during TENS (i.e. as a standard crossover) and detected no statistically significant effects between coffee and decaffeinated drinks for the natural logarithm (ln) transformed values of electrical pain threshold [ln EPT Coffee-ln EPT Decaffeinated coffee mean (standard error) = 0.0147 (0.2159)], mechanical pain threshold [ln MPT Coffee-ln MPT Decaffeinated coffee mean (standard error) = 0.1296 (0.0816)] and cold pain threshold [ln CPT Coffee-ln CPT Decaffeinated coffee mean (standard error) = 0.0793 (0.1139)]. We conclude that a single cup of coffee (100 mg caffeine) had no detectable effect on TENS outcome. Reasons why coffee did not produce a detectable effect on pain threshold are discussed.
-
Clin Physiol Funct Imaging · Jul 2009
Inert gas rebreathing: the effect of haemoglobin based pulmonary shunt flow correction on the accuracy of cardiac output measurements in clinical practice.
Cardiac output (CO) is an important cardiac parameter, however its determination is difficult in clinical routine. Non-invasive inert gas rebreathing (IGR) measurements yielded promising results in recent studies. It directly measures pulmonary blood flow (PBF) which equals CO in absence of significant pulmonary shunt flow (Q(S)). A reliable shunt correction requiring the haemoglobin concentration (c(Hb)) as only value to be entered manually has been implemented. Therefore, the aim of the study was to evaluate the effect of various approaches to Q(S) correction on the accuracy of IGR. ⋯ IGR allows a reliable non-invasive determination of CO. Since PBF significantly increased the measurement bias, shunt correction should always be applied. A fixed c(Hb) of 14.0 g dl(-1) can be used for both genders if the exact c(Hb) value is not known. Nevertheless, the individual value should be used if any possible.
-
Clin Physiol Funct Imaging · Jul 2009
Heart rate variability during sleep and sleep apnoea in a population based study of 387 women.
Increased sympathetic activity during sleep has been suggested as a link between obstructive sleep apnoea syndrome and cardiovascular disease. Heart rate variability (HRV) is a measure of autonomic effect on the heart. Different parameters have been associated with sympathetic and parasympathetic activity. ⋯ In slow wave sleep the parameters decreased. In conclusion, moderately increased prevalence of obstructive apnoeas was associated with signs of higher sympathetic activity. High AHI was however associated with a HRV-pattern suggestive of depressed sympathetic drive and lowered ability to increase it during REM.