• Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi · Oct 2007

    Application of artificial vertebral body of biomimetic nano-hydroxyapatite/polyamide 66 composite in anterior surgical treatment of thoracolumbar fractures.

    • Yunsheng Ou, Dianming Jiang, Zhengxue Quan, Hong An, and Bo Liu.
    • Department of Orthopaedics, First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, PR China. ouyunsheng2001@yahoo.com.cn
    • Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2007 Oct 1;21(10):1084-8.

    ObjectiveTo study the clinical effects of the artificial vertebral body of the biomimetic nano-hydroxyapatite/ polyamide 66 (n-HA/PA66) composite for the structural reconstruction and the height restoring of the vertebral body in the thoracolumbar fractures by the anterior surgical procedures.MethodsFrom December 2003 to January 2006, 42 patients with thoracolumbar fractures received the anterior surgical procedures to decompress and reconstruct the spinal vertebral structure with the artificial vertebral body of the n-HA/PA66 composite. Among the patients, there were 28 males and 14 females, aged 17-67 years, averaged 43.6 years. The thoracolumbar fractures developed at T12 in 5 patients, at L1 in 17, at L2 in 14, and at L3 in 6. The height of the anterior border of the vertebral body amounted to 29%-47% of the vertebral body height, averaged 40.6%. The Cobb angle on the sagittal plane was 21-38 degrees averaged 27.6 degrees. According to the Frankel grading scale, the injuries to the nerves were as the following: Grade A in 7 patients, Grade B in 19, Grade C in 8, Grade D in 6, and Grade E in 2.ResultsAll the 42 patients were followed up for 6-25 months. Among the patients, 36 were reconstructed almost based on the normal anatomic structure, and 6 were well reconstructed. The mean height of the anterior border of the vertebral body was 40.6% of the vertebral body height before operation but 91.7% after operation. And the reconstructed height of the vertebra was maintained. The mean Cobb angle on the sagittal plane was 27.6 degrees before operation but 13.4 degrees after operation. All the patients had a recovery of the neurological function that had a 1-grade or 2-grade improvement except 7 patients who were still in Grade A and 2 patients who were in Grade D. The implant was fused 3-5 months after operation. No infection, nail break, bar/ plate break or loosening of the internal fixation occurred.ConclusionThe artificial vertebral body of the biomimetic n-HA/PA66 composite can effectively restore the height and the structure of the vertebra, can be fused with the vertebral body to reconstruct the spinal structural stability effectively, and can be extensively used in the clinical practice.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…