Ann Fr Anesth Reanim · Jan 2000
Comparative Study[Performance studies of 6 new anesthesia ventilators: bench tests].
- S Jaber, N Langlais, B Fumagalli, S Cornec, L Beydon, A Harf, and L Brochard.
- Réanimation médicale et Inserm U492, CHU Henri-Mondor, Créteil, France.
- Ann Fr Anesth Reanim. 2000 Jan 1;19(1):16-22.
ObjectiveTo assess the pneumatic performances of six new anaesthesia ventilators.Study DesignBench test study.MaterialThe study included one ventilator operated by an electric motor: ABT 5300 (Kontron); four ventilators of "bellows-in-bottle" category: ADU version 97 (Datex-Ohmeda); Aestiva 3000 (Datex-Ohmeda), Kion (Siemens), the two versions of Julian (Dräger); and an original ventilator devised for quantitative, or self-regulating target controlled inhalation anaesthesia, with a totally closed circuit, made of four ventilating chambers: PhysioFlex (Dräger).MethodsThe bench test included a passive lung model with adjustable compliance and resistances, and flow and pressure gauges. The accuracy of volume and pressure measurements was tested in various conditions of resistance and compliance.ResultsPneumatic performance and accuracy were satisfactory, even in severe ventilatory conditions. All the ventilators, except ABT 5300 and Julian 1, have a compliance compensation system permitting to deliver and to maintain a constant tidal volume under various conditions of downstream load, particularly under maximal load condition. Variations of tidal volume with the increase of the fresh gas flow are negligible.ConclusionRecent technological progress has improved pneumatic performance of anaesthesia ventilators and the marketed models are more homogeneous at present. Ergonomics and training for the use of the machine are becoming major criteria for the global assessment and the choice of a ventilator.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.