• NeuroImage · Mar 2015

    Comparative Study

    Comparison between balanced steady-state free precession and standard spoiled gradient echo magnetization transfer ratio imaging in multiple sclerosis: methodical and clinical considerations.

    • Michael Amann, Till Sprenger, Yvonne Naegelin, Julia Reinhardt, Pascal Kuster, Jochen G Hirsch, Ludwig Kappos, Ernst-Wilhelm Radue, Christoph Stippich, and Oliver Bieri.
    • Department of Neurology, University Hospital Basel, Petersgraben 4, 4031 Basel, Switzerland; Division of Diagnostic and Interventional Neuroradiology, Department of Radiology, University Hospital Basel, Petersgraben 4, 4031 Basel, Switzerland; Medical Image Analysis Center (MIAC), Schanzenstrasse 55, 4031 Basel, Switzerland. Electronic address: Michael.Amann@usb.ch.
    • Neuroimage. 2015 Mar 1;108:87-94.

    AbstractDifferent pathological processes like demyelination and axonal loss can alter the magnetisation transfer ratio (MTR) in brain tissue. The standard method to measure this effect is to scan the respective tissue twice, one with and one without a specific saturation pulse. A major drawback of this technique based on spoiled gradient echo (GRE) sequences relates to its long acquisition time due to the saturation pulses. Recently, an alternative concept for MT imaging based on balanced steady state free precession (bSSFP) has been proposed. Modification of the duration of the radiofrequency pulses for imaging allows scanning MT sensitive and non-sensitive images. The steady-state character of bSSFP with high intrinsic signal-to-noise ratio (SNR) allows three-dimensional (3D) whole brain MTR at high spatial resolution within short and thus clinically feasible acquisition times. In the present study, both bSSFP-MT and 2D GRE-MT imaging were used in a cohort of 31 patients with multiple sclerosis (MS) to characterize different normal appearing (NA) and pathological brain structures. Under the constraint of identical SNR and scan time, a 3.4 times higher voxel size could be achieved with bSSFP. This increased resolution allowed a more accurate delineation of the different brain structures, especially of cortex, hippocampus and MS lesions. In a multiple linear regression model, we found an association between MTR of cortical lesions and a clinical measure of disability (r= -0.407, p=0.035) in the bSSFP dataset only. The different relaxation weighting of the base images (T2/T1 in bSSFP, proton density in GRE) had no effects besides a larger spreading of the MTR values of the different NA structures. This was demonstrated by the nearly perfect linearity between the NA matter MTR of both techniques as well as in the absolute MTR differences between NA matter and the respective lesions.Copyright © 2014 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…