• NMR in biomedicine · Sep 2013

    Assessment of PDA shunt and systemic blood flow in newborns using cardiac MRI.

    • Kathryn M Broadhouse, Anthony N Price, Giuliana Durighel, David J Cox, Anna E Finnemore, A David Edwards, Joseph V Hajnal, and Alan M Groves.
    • Neonatal Medicine and Imaging Sciences Division, Imperial College London, MRC Clinical Sciences Centre, Hammersmith Hospital, Du Cane Road, London, UK.
    • NMR Biomed. 2013 Sep 1;26(9):1135-41.

    AbstractPatent ductus arteriosus (PDA) remains common in preterm newborns, but uncertainty over optimal management is perpetuated by clinicians' inability to quantify its true haemodynamic impact. Our aim was to develop a technique to quantify ductal shunt volume and the effect of PDA on systemic blood flow volume in neonates. Phase contrast MRI sequences were optimized to quantify left ventricular output (LVO) and blood flow in the distal superior vena cava (SVC) (below the azygos vein insertion), descending aorta (DAo) and azygos vein. Total systemic flow was measured as SVC + DAo-azygos flow. Echo measures were included and correlated to shunt volumes. 75 infants with median (range) corrected gestation 33(+6) (26(+4) -38(+6) ) weeks were assessed. PDA was present in 15. In 60 infants without PDA, LVO matched total systemic flow (mean difference 2.06 ml/kg/min, repeatability index 13.2%). In PDA infants, ductal shunt volume was 7.9-74.2% of LVO. Multiple linear regression analysis correcting for gestational age showed that there was a significant association between ductal shunt volume and decreased upper and lower body flow (p = 0.01 and p < 0.001). However, upper body blood flow volumes were within the control group 95% confidence limits in all 15 infants with PDA, and lower body flow volumes within the control group limits in 12 infants with PDA. Echocardiographic assessment of reversed diastolic flow in the descending aorta had the strongest correlation with ductal shunt volume. We have demonstrated that quantification of shunt volume is feasible in neonates. In the presence of high volume ductal shunting the upper and lower body flow volume are somewhat reduced, but levels remain within or close to the normal range for preterm infants.Copyright © 2013 John Wiley & Sons, Ltd.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…