    Performance of the coughassist insufflation-exsufflation device in the presence of an endotracheal tube or tracheostomy tube: a bench study.

    • Claude Guérin, Gaël Bourdin, Véronique Leray, Bertrand Delannoy, Frédérique Bayle, Michèle Germain, and Jean-Christophe Richard.
    • Service de Réanimation Médicale et d'Assistance Respiratoire, Hôpital de la Croix Rousse, Lyon, France. claude.guerin@chu-lyon.fr
    • Resp Care. 2011 Aug 1;56(8):1108-14.

    BackgroundThe CoughAssist is a mechanical insufflator-exsufflator designed to assist airway secretion clearance in patients with ineffective cough. The device may benefit intubated and tracheotomized patients. We assessed the impact of various artificial airways on peak expiratory flow (PEF) with the CoughAssist.MethodsWe measured PEF and pressure at the airway opening in a lung model during insufflation-exsufflation with the CoughAssist, at 3 set pressures: 30/-30, 40/-40, and 50/-50 cm H(2)O, first without (control), and then with different sizes (6.5 to 8.5 mm inner diameter) of endotracheal tube (ETT) and tracheostomy tube (6, 7, and 8 mm inner diameter), compliance settings of 30 and 60 mL/cm H(2)O, and resistance settings of 0 and 5 cm H(2)O/L/s). We analyzed the relationship between PEF and pressure with linear regression.ResultsWith compliance of 30 mL/cm H(2)O and 0 resistance the slope of the control relationship between PEF and pressure was statistically significantly greater than during any conditions with ETT or tracheostomy tube. Therefore, in comparison to the control, the relationship of PEF to pressure significantly went in the direction from top to bottom as the ETT or tracheostomy tube became narrower. The findings were the same with compliance of 30 mL/cm H(2)O and resistance of 5 cm H(2)O/L/s. With compliance of 60 mL/cm H(2)O the highest set pressure values were not achieved and some relationships departed from linearity. The control slope of the relationship between PEF and pressure with compliance of 60 mL/cm H(2)O and 0 resistance did not significantly differ with any ETT or tracheostomy tube.ConclusionsThe artificial airways significantly reduced PEF during insufflation-exsufflation with CoughAssist; the narrower the inner diameter of the artificial airway, the lower the PEF for a given expiratory pressure.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…