• Anesthesia and analgesia · Jan 2014

    Noninvasive monitoring of lung recruitment maneuvers in morbidly obese patients: the role of pulse oximetry and volumetric capnography.

    • Gerardo Tusman, Iván Groisman, Felipe E Fiolo, Adriana Scandurra, Jorge Martinez Arca, Gustavo Krumrick, Stephan H Bohm, and Fernando Suarez Sipmann.
    • From the Departments of *Anesthesia and †Surgery, Hospital Privado de Comunidad, Mar del Plata, Buenos Aires; ‡Bioengineering Laboratory, Electronic Department, School of Engineering, Mar del Plata University, Mar del Plata, Argentina; §Swisstom AG, Landquart, Switzerland; ‖Department of Surgical Sciences, Clinical Physiology, Uppsala University Hospital, Uppsala, Sweden; and ¶Instituto de Investigación Santinaria, Fundación Jiménez Díaz, IIS-FJD, CIBERES, Madrid, Spain.
    • Anesth. Analg.. 2014 Jan 1;118(1):137-44.

    BackgroundWe conducted this study to determine whether pulse oximetry and volumetric capnography (VCap) can determine the opening and closing pressures of lungs of anesthetized morbidly obese patients.MethodsTwenty morbidly obese patients undergoing laparoscopic bariatric surgery with capnoperitoneum were studied. A lung recruitment maneuver was performed in pressure control ventilation as follows: (1) During an ascending limb, the lungs' opening pressure was detected. After increasing positive end-expiratory pressure (PEEP) from 8 to 16 cm H2O, fraction of inspired oxygen (FIO2) was decreased until pulse oximetric arterial saturation (SpO2) was <92%. Thereafter, end-inspiratory pressure was increased in steps of 2 cm H2O, from 36 to a maximum of 50 cm H2O. The opening pressure was attained when SpO2 exceeded 97%. (2) During a subsequent decreasing limb, the lungs' closing pressure was identified. PEEP was decreased from 22 to 10 cm H2O in steps of 2 cm H2O. The closing pressure was determined as the PEEP value at which respiratory compliance decreased from its maximum value. We continuously recorded lung mechanics, SpO2, and VCap.ResultsThe lungs' opening pressures were detected at 44 (4) cm H2O (median and interquartile range) and the closing pressure at 14 (2) cm H2O. Therefore, the level of PEEP that kept the lungs without collapse was found to be 16 (3) cm H2O. Using respiratory compliance as a reference, receiver operating characteristic analysis showed that SpO2 (area under the curve [AUC] 0.80 [SE 0.07], sensitivity 0.65, and specificity 0.94), the elimination of CO2 per breath (AUC 0.91 [SE 0.05], sensitivity 0.85, and specificity 0.98), and Bohr's dead space (AUC 0.83 [SE 0.06], sensitivity 0.70, and specificity 0.95] were relatively accurate for detecting lung collapse during the decreasing limb of a recruitment maneuver.ConclusionsLung recruitment in morbidly obese patients could be effectively monitored by combining noninvasive pulse oximetry and VCap. SpO2, the elimination of CO2, and Bohr's dead space detected the individual's opening and closing pressures.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.