• Academic radiology · Jan 2005

    Intensity-based 2D-3D spine image registration incorporating a single fiducial marker.

    • Daniel B Russakoff, Torsten Rohlfing, John R Adler, and Calvin R Maurer.
    • Department of Computer Science, Stanford University, 300 Pasteur Drive, Stanford, CA 94305-5327, USA.
    • Acad Radiol. 2005 Jan 1;12(1):37-50.

    Rationale And ObjectivesThe two-dimensional (2D)-three dimensional (3D) registration of a computed tomography image to one or more x-ray projection images has a number of image-guided therapy applications. In general, fiducial marker-based methods are fast, accurate, and robust, but marker implantation is not always possible, often is considered too invasive to be clinically acceptable, and entails risk. There also is the unresolved issue of whether it is acceptable to leave markers permanently implanted. Intensity-based registration methods do not require the use of markers and can be automated because such geometric features as points and surfaces do not need to be segmented from the images. However, for spine images, intensity-based methods are susceptible to local optima in the cost function and thus need initial transformations that are close to the correct transformation.Materials And MethodsIn this report, we propose a hybrid similarity measure for 2D-3D registration that is a weighted combination of an intensity-based similarity measure (mutual information) and a point-based measure using one fiducial marker. We evaluate its registration accuracy and robustness by using gold-standard clinical spine image data from four patients.ResultsMean registration errors for successful registrations for the four patients were 1.3 and 1.1 mm for the intensity-based and hybrid similarity measures, respectively. Whereas the percentage of successful intensity-based registrations (registration error < 2.5 mm) decreased rapidly as the initial transformation got further from the correct transformation, the incorporation of a single marker produced successful registrations more than 99% of the time independent of the initial transformation.ConclusionThe use of one fiducial marker reduces 2D-3D spine image registration error slightly and improves robustness substantially. The findings are potentially relevant for image-guided therapy. If one marker is sufficient to obtain clinically acceptable registration accuracy and robustness, as the preliminary results using the proposed hybrid similarity measure suggest, the marker can be placed on a spinous process, which could be accomplished without penetrating muscle or using fluoroscopic guidance, and such a marker could be removed relatively easily.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.