Pacing Clin Electrophysiol · Jul 1990
Comparative StudyAtrial and ventricular stimulation threshold development: a comparative study in patients with a DDD pacemaker and two identical carbon-tip leads.
- J Brandt, R Attewell, T Fåhraeus, and H Schüller.
- Department of Cardiothoracic Surgery, University Hospital, Lund, Sweden.
- Pacing Clin Electrophysiol. 1990 Jul 1;13(7):859-66.
AbstractThe atrial and ventricular pacing threshold development during the first postoperative year was studied in a group of patients receiving DDD pacemakers. Identical carbon-tip endocardial leads were implanted in atrium and ventricle. Atrial and ventricular voltage stimulation thresholds were measured at implantation, and noninvasively at 1 and 12 months thereafter. The atrial amplifier sensitivity required for adequate P wave sensing during follow-up was also determined. The possible influence of a number of factors upon atrial and ventricular threshold evolution was statistically assessed. The threshold data were complete in 57 patients (mean age +/- SD, 65.2 +/- 12.4 years). Thirteen patients had a diagnosis of sinus node disease, whereas 44 had not. Patient age and diagnosis did not significantly influence atrial or ventricular stimulation threshold development. Atrial sensing thresholds were not related to atrial stimulation thresholds during follow-up. Atrial pacing thresholds were higher than ventricular thresholds at pacemaker implantation (P less than 0.00005), but the postoperative threshold rise and thresholds at 1 and 12 months postoperatively did not differ significantly between the atrium and ventricle. The ratio of chronic to acute stimulation thresholds was higher on the ventricular than on the atrial level (0.001 greater than P greater than 0.0005). The chronic atrial threshold showed a logarithmic relation to the threshold at implantation (P = 0.0006); postoperative threshold rise was not a significant determinant of the chronic atrial threshold (P = NS). On the ventricular level, the reverse was seen: The chronic threshold was related to the postoperative threshold rise (P = 0.0015, logarithmic relation), but not to the implantation threshold (P = NS).(ABSTRACT TRUNCATED AT 250 WORDS)
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.